Sound insulation covers all construction measures that prevent sound from travelling from one room to another or from outside to inside. In building construction it is described by ratings such as the weighted apparent sound reduction index R′w for airborne sound and the weighted normalised impact sound pressure level L′n,w for impact sound. In Germany it is regulated by DIN 4109, in England and Wales by Approved Document E.
- Sound insulation prevents transmission between rooms. Room acoustics, by contrast, improve the sound within the room itself. These are two different tasks.
- Airborne sound is rated with R′w, where higher is better. Impact sound is rated with L′n,w, where lower is better.
- A large share of sound can be transmitted via flanking elements, not just through the separating wall or separating floor.
- Quiet building elements combine mass, decoupling based on the mass-spring-mass principle and airtight, decoupled junctions.
- The minimum requirements in Germany are set out in DIN 4109-1. Enhanced sound insulation must be agreed in the contract.
Sound insulation, soundproofing, sound absorption: the terms clearly defined
In everyday language these terms are often mixed up. For design and construction, however, the distinction is crucial, because it leads to completely different measures.
| Term | What it describes | Ratings and standards |
|---|---|---|
| Acoustic protection (Schallschutz) | Umbrella term for all measures against sound transmission in and around buildings | DIN 4109, VDI 4100 |
| Sound insulation | Reduction of sound transmission through a building element between two rooms | R′w, L′n,w |
| Sound absorption | Conversion of sound energy into heat at surfaces within the room, reduces reverberation | Absorption coefficient α, reverberation time, DIN 18041 |
| Noise control | Protection against environmental noise, for example with noise barriers along roads | Environmental noise legislation, in buildings external elements to DIN 4109-1 |
An acoustic panel on the wall makes an echoey room more pleasant, but does little to protect you from the neighbours. Conversely, a separating floor with excellent sound insulation does not make a room with hard surfaces sound good.
What is sound? Frequency, level and decibels
Sound consists of mechanical vibrations that travel through air as airborne sound and through solid materials as structure-borne sound. The frequency in hertz (Hz) determines the pitch. Depending on age, the human ear perceives roughly 16 Hz to 16,000 Hz, and the literature often quotes 20 Hz to 20,000 Hz. The sound insulation of building elements is rated over the range from 100 to 3150 Hz, with lower frequencies down to 50 Hz taken into account through spectrum adaptation terms.
The strength of sound is given as a level in decibels (dB). The scale is logarithmic, so small numerical differences have a bigger effect than you might think.

- +3 dB corresponds to doubling the sound energy, for example two equally loud sources instead of one.
- +10 dB is perceived as roughly twice as loud.
- Conversely, a building element that performs 3 dB better halves the transmitted sound energy. 10 dB more insulation lets through only a tenth of the energy.
Airborne, impact and structure-borne sound: how sound travels through a building

Airborne sound
Voices, music or a television set the air vibrating. When this airborne sound strikes a wall or floor, it excites bending vibrations that are radiated as sound again on the other side. How well a building element prevents this is described by the sound reduction index R. It is the logarithmic ratio of incident to transmitted sound power: R = 10 · lg(W1/W2) in dB.
Impact sound and structure-borne sound
Footsteps, chairs being moved, children jumping or a washing machine on spin excite the floor mechanically. This structure-borne sound spreads through the structure and becomes audible again as airborne sound in other rooms, not only directly below but also diagonally and to the side. It is measured with a standard tapping machine on the floor and expressed as the normalised impact sound pressure level Ln in the room below. The rule here: the lower the level, the better the floor.
Flanking transmission
Sound finds detours. Via adjoining external walls, continuous floors, screeds or service shafts it bypasses the actual separating element. How much gets through these flanking paths depends on the junctions where the elements are connected. This is why a distinction is made between the laboratory value Rw, measured in a test rig without flanking paths, and the field value R′w with a prime, which includes flanking transmission in the building. Flanking paths are particularly important in timber and lightweight construction. According to the data sheet, resilient decoupling strips such as PhoneStrip under walls and at module joints improve the vibration reduction index.
Sound bridges
A sound bridge is a rigid connection between two leaves that should be decoupled, for example a missing perimeter edge strip on the screed or a pipe running through the insulation layer without sleeving. It can largely cancel out the effect of an otherwise good construction. Find out more in our article on the mass-spring-mass principle.
Sound insulation ratings at a glance: Rw, R′w, Ln,w and more
| Rating | Meaning | Better is |
|---|---|---|
| Rw | Weighted sound reduction index of a building element in the laboratory, without flanking paths | higher |
| R′w | Weighted apparent sound reduction index in the building, including flanking transmission, requirement value in DIN 4109-1 | higher |
| DnT,w | Weighted standardised level difference, referenced to the reverberation time, used in VDI 4100 and DEGA 103 | higher |
| Ln,w | Weighted normalised impact sound pressure level of a floor in the laboratory | lower |
| L′n,w | Weighted normalised impact sound pressure level in the building, requirement value in DIN 4109-1 | lower |
| ΔLw | Weighted reduction in impact sound pressure level of a floor covering such as screed or flooring | higher |
| ΔRw | Weighted improvement in sound reduction index from an additional lining such as an independent wall lining | higher |
| C, Ctr, CI | Spectrum adaptation terms: C for living noise and medium to high frequency noise, Ctr for low frequency noise such as urban traffic, CI for footstep noise | added to the single-number rating |
The single-number ratings are derived from measurements in one-third octave bands to DIN EN ISO 717-1 for airborne sound and DIN EN ISO 717-2 for impact sound, published in the UK as BS EN ISO 717-1 and BS EN ISO 717-2. A standardised reference curve is shifted until it fits the measured curve.
The Rw from the data sheet is not the R′w in the finished building. Because of flanking transmission, field values are usually lower. Designers therefore use the prediction method to DIN 4109-2 with an allowance for prediction uncertainty uprog. The same applies to improvement values: if an independent wall lining achieves, for example, ΔRw = 12 dB, R′w in the building does not automatically rise by 12 dB, because flanking paths limit the improvement. Find out more in DIN 4109 explained.
Which principles make a building element quiet?
1. Mass
Heavy building elements are harder to set vibrating. According to the mass law, the airborne sound insulation of single-leaf elements theoretically increases by about 6 dB for every doubling of the mass per unit area. The limit is set by coincidence: stiff panels show a dip at the critical frequency. Materials that are heavy and at the same time flexible are therefore ideal. The PhoneStar acoustic board, made of quartz sand and honeycomb cardboard, reaches 29 kg/m² and Rw 42 dB according to the data sheet in the 15 mm Plus Tri version, and its critical frequency is above 7000 Hz.
2. Decoupling
Two leaves separated by a soft layer insulate considerably better above their resonance frequency than a single leaf of the same mass. This is how floating screeds, independent wall linings and twin-leaf walls work. Our article on the mass-spring-mass principle shows how to calculate the resonance frequency.
3. Airtightness
Sound passes through every opening. Open joints, back-to-back sockets, poorly sealed doors or unsealed pipe penetrations can significantly reduce the sound insulation of a building element. Airtight junctions are therefore also a sound insulation measure.
4. Cavity absorption
Mineral wool in the cavities of stud walls and floor constructions damps standing waves in the cavity. On its own, however, mineral wool provides hardly any airborne sound insulation because of its low mass.
5. Decoupled junctions
Where walls and floors meet, the design of the junction determines the flanking transmission. Resilient bearings, separated elements and decoupling strips reduce the transmission of structure-borne sound.
How much sound insulation is required?
In Germany, DIN 4109-1:2018-01 sets the minimum requirements. It is adopted into building regulations through the federal states’ technical building rules. Between dwellings, for example, the requirements are R′w ≥ 53 dB for walls, R′w ≥ 54 dB for floors and an impact sound level L′n,w ≤ 50 dB. In England, Approved Document E sets the performance standards for separating walls and floors, expressed as on-site values for airborne and impact sound, so German and UK figures cannot be compared one to one.
These values protect against unreasonable disturbance, but they do not describe comfort. In 2007 the German Federal Court of Justice ruled that the minimum values of DIN 4109 do not correspond to the usual standard of quality and comfort. Higher values can be found in DIN 4109-5, VDI 4100 and DEGA guideline 103-1.
Agree the sound insulation in the contract with specific figures, not just with “to DIN 4109” or “to Building Regulations”. All values and background can be found in our article on DIN 4109.
Sound insulation in timber construction and refurbishment
Lightweight constructions have little mass. Low-frequency footstep noise is therefore the biggest challenge for timber joist floors and cross-laminated timber. Proven solutions include adding mass to the floor, for example with loose fill or heavy dry screed boards, decoupled ceilings and decoupled junctions. In refurbishment, low build-up heights and the limited load capacity of old floors add to the challenge. Dry build-ups deliver sound insulation here without moisture or drying time. You will find solutions on our page dry screed in refurbishment and in our tested system build-ups.
Common mistakes that cost sound insulation
- Perimeter edge strips are missing or are cut off before the floor covering is laid.
- The screed runs continuously under the separating wall or under doors between two dwellings.
- Pipes and cables are routed rigidly through floors and screed.
- Skirting boards are fixed to the floor or sealed to both floor and wall.
- Sockets and switches are placed directly opposite each other in lightweight walls.
- Design is based only on the laboratory value from the data sheet, without considering flanking paths.
Frequently asked questions about sound insulation
In construction, sound insulation means protection in and around buildings, i.e. insulation between rooms and against external noise via the facade and windows. Noise control usually refers to measures against environmental noise, such as noise barriers along roads and railway lines.
Sound insulation reduces the transmission of sound through a building element into another room. Sound absorption converts sound into heat at surfaces within the room and so reduces reverberation. Only insulation helps against noise from the neighbours.
Yes. In Germany, the minimum requirements of DIN 4109-1 are adopted into building regulations through the federal states’ technical building rules. In England, Approved Document E applies. Anything beyond the minimum must be agreed in the contract.
It depends on the rating. For the sound reduction index R′w for airborne sound, a higher value is better. For the impact sound level L′n,w, a lower value is better, because it indicates how much sound arrives in the room below.
The prime indicates a value in the installed condition. R′w includes transmission via flanking elements, whereas Rw without a prime describes only the element itself in the laboratory. On site, values are therefore usually lower than on the data sheet.
There is no one-size-fits-all answer. Very good values are achieved by heavy single-leaf masonry walls and by twin-leaf, decoupled constructions, including in timber and drylining. Besides the wall build-up, the junctions with floors, ceilings and external walls are decisive.
Only to a limited extent. Mineral wool damps cavities in twin-leaf constructions, but has hardly any mass itself. Without heavy boarding and decoupling it provides little airborne sound insulation.
Sources
- DIN 4109-1:2018-01 Sound insulation in buildings, Part 1: Minimum requirements. DIN Media.
- DIN EN ISO 717-1:2021-05 and DIN EN ISO 717-2:2021-05 Rating of sound insulation in buildings and of building elements. DIN Media.
- DIN 18041:2016-03 Acoustic quality in rooms. DIN Media.
- Bayerisches Landesamt für Umwelt: Noise, hearing, measuring and assessing (UmweltWissen).
- Baunetz Wissen Akustik: Sound insulation of single-leaf walls.
- German Federal Court of Justice (BGH), judgment of 14.06.2007, VII ZR 45/06.
- DEGA guideline 103-1:2024-09 Sound insulation in residential buildings, sound insulation classes.
- Wolf Bavaria: PhoneStar and PhoneStrip data sheets.