Measured in the laboratoryDry construction

Cross-laminated timber ribbed slab with dry screed

System designation LIGNO_Rippe_Q3_Akustik_196mm

Build-up from the top 2x15 Tri/20 MiWo EP3/15 HFD

Tested floor assembly on a CLT ribbed slab. In the laboratory, the assembly achieves a weighted normalised impact sound pressure level of 44 dB and a weighted sound reduction index of 67 dB. The assembly is installed entirely dry, with no drying time. The values are achieved without a ceiling lining, so the timber soffit can remain exposed.

Section drawing · dimensions in mm
44dB
Impact sound Ln,wCI = 3 dB · laboratory
67dB
Airborne sound RwLaboratory
261mm
Total build-upincluding the structural floor
190.7kg/m²
Mass per unit areaTotal build-up
Charring to EC5
Fire resistance from belowfrom above: unclassified
Bestseller for concrete floor slabs
Wolf Bavaria system assembly

The assembly layer by layer

Section drawing and isometric view of the tested assembly LIGNO_Rippe_Q3_Akustik_196mm, with all layer thicknesses. Select a layer in the drawing, the legend or the layer list to see its function.

Total thickness incl. structural floor Impact sound Ln,w = 44 dBAirborne sound Rw = 67 dBDry screedValues according to the test report
Tip: use ↑ ↓ to step through the layers
ItemLayerThickness [mm]
In brief

Key facts at a glance

  • Tested: Impact sound Ln,w = 44 dB and airborne sound Rw = 67 dB in the laboratory, documented in the test report.
  • Dry installation: no drying time, so the following trades can start promptly.
  • 261 mm total build-up including the structural floor.
  • All documents free of charge: Section drawing, test report, specification text and data sheets as PDFs by email.

Request planning documents

Explainer video · 1:40

System assemblies explained in 100 seconds

Architect Tina designs, developer Thorsten needs the evidence, building physicist Patrick checks it. Markus Schramm shows why our system assemblies are already tested and how our technical application team supports you with your own assemblies.

Ask a technical question
Explainer video thumbnail, system assemblies: over 50 tested assemblies 1:40

The video is only loaded from YouTube when you play it.

For your design

What this assembly means for you

Designers, tradespeople and developers look at different details. Choose who you are.

Design
Installation
Build and buy
Cartoon figure of architects

Design

Architects

What do I need to know for design and tendering?

  • 261 mm total build-upIncluding the structural floor. Mass per unit area 190.7 kg/m².
  • Fire resistanceFrom above without classification, from below charring to EC5.
  • Ceiling liningNone, the floor soffit remains exposed.
  • Use categoryA1–B2.
  • Ready for tenderItem-by-item specification text for all layers, matching the tested assembly.
Technical data

All performance values at a glance

The values are taken from the test report. They apply to the laboratory test rig without flanking transmission; values in the building depend on the junctions.

System designation
LIGNO_Rippe_Q3_Akustik_196mm
Build-up from the top
2x15 Tri/20 MiWo EP3/15 HFD
Floor type
CLT ribbed slab
Screed
Dry screed
Ceiling lining
none
Screed
2 × 15 mm PhoneStar Tri acoustic boards, m’ = 39.0 kg/m²
Insulation board
20 mm screed insulation boards, m’ = 3.8 kg/m²
Insulation board
15 mm wood fibre insulation boards, m’ = 3.8 kg/m²
Structural slab
196 mm CLT ribbed elements, m’ = 144.1 kg/m²
Weighted normalised impact sound pressure level
Ln,w (CI) = 44 (3) dB
Weighted sound reduction index
Rw = 67 dB (C; Ctr = -4; -11 dB)
Mass per unit area
190.7 kg/m²
Total build-up thickness
261 mm
Use category
A1–B2
Fire resistance from above
unclassified
Fire resistance from below
Charring to EC5
Test evidence
Test report PB 18-002898-PR02 PB X01-F03-04-de
Manufacturer
Wolf Bavaria GmbH, Heilsbronn

Good to know

Need a different assembly? If none of our tested assemblies fits, our technical application team will work with you and our partners to develop a bespoke assembly and have it tested.

On-site values depend on flanking paths, junctions and penetrations. On request, we can measure the sound insulation in the laboratory or directly on site.

Variants

Similar assemblies: CLT ribbed slab

Assemblies on the same floor type with comparable performance data. For both values, a longer bar means better sound insulation: lower impact sound level, higher airborne sound insulation.

VariantLn,wRwThickness
LIGNO_Rippe_Q3_Akustik_196mmRibbed slab44 dB67 dB261 mmThis page
LIGNO_Rippe_Q3_Akustik_196mm_HugoRibbed slab44 dB69 dB279 mmView →

You will find all 55 floor assemblies, with filters and direct comparison, in the Assemblies overview →

Everything from a single source

Request design documents for this assembly

You will receive the complete package by email, tailored to this assembly. On request, our technical application team will contact you personally.

  • Test report PB 18-002898-PR02 PB X01-F03-04-deCover sheet
  • ETA-20/0371 PhoneStar acoustic boards
  • PhoneStar Tri data sheet
  • Data sheet: Wolf wood fibre insulation board
  • Installation instructions for Wolf Bavaria systems
  • Wolf system solutions specification text: solid timber floor
  • Test report PB 18-002898-PR02 PB X01-F03-04-decomplete
  • Personal consultationOur technical application team checks variants for your project
Markus Schramm, Wolf Bavaria, in productionMarkus Schramm as a cartoon character from the explainer video
“My team and I will be happy to help you personally with any technical questions. Please feel free to send us an enquiry.”

Markus SchrammM.Eng., Dipl.-Ing. (FH)
Head of Technical and Building Acoustics

Request documents

Assembly: LIGNO_Rippe_Q3_Akustik_196mm