Measured in the laboratoryDry construction

Concrete floor slab with dry screed

System designation BM 1.6.1 22 WF UDP

Build-up from the top 2x12,5 ST Tri/22 HFD UDP

Tested floor assembly on a concrete floor slab. In the laboratory, the assembly achieves a weighted normalised impact sound pressure level of 54 dB and a weighted sound reduction index of 67 dB. The assembly is installed entirely dry, with no drying time.

Section drawing · dimensions in mm
54dB
Impact sound Ln,wCI = -1 dB · laboratory
67dB
Airborne sound RwLaboratory
207mm
Total build-upincluding the structural floor
423.3kg/m²
Mass per unit areaTotal build-up
REI90
Fire resistance from belowfrom above: unclassified
Bestseller for concrete floor slabs
Wolf Bavaria system assembly

The assembly layer by layer

Section drawing and isometric view of the tested assembly BM 1.6.1 22 WF UDP, with all layer thicknesses. Select a layer in the drawing, the legend or the layer list to see its function.

Total thickness incl. structural floor Impact sound Ln,w = 54 dBAirborne sound Rw = 67 dBDry screedValues according to the test report
Tip: use ↑ ↓ to step through the layers
ItemLayerThickness [mm]
In brief

Key facts at a glance

  • Tested: Impact sound Ln,w = 54 dB and airborne sound Rw = 67 dB in the laboratory, documented in the test report.
  • Dry installation: no drying time, so the following trades can start promptly.
  • 207 mm total build-up including the structural floor.
  • All documents free of charge: Section drawing, test report, specification text and data sheets as PDFs by email.

Request planning documents

Explainer video · 1:40

System assemblies explained in 100 seconds

Architect Tina designs, developer Thorsten needs the evidence, building physicist Patrick checks it. Markus Schramm shows why our system assemblies are already tested and how our technical application team supports you with your own assemblies.

Ask a technical question
Explainer video thumbnail, system assemblies: over 50 tested assemblies 1:40

The video is only loaded from YouTube when you play it.

For your design

What this assembly means for you

Designers, tradespeople and developers look at different details. Choose who you are.

Design
Installation
Build and buy
Cartoon figure of architects

Design

Architects

What do I need to know for design and tendering?

  • 207 mm total build-upIncluding the structural slab. Mass per unit area 423.3 kg/m².
  • Fire resistanceFrom above: unclassified, from below: REI90.
  • Ceiling liningNone, the floor soffit remains exposed.
  • Use categoryConsult the manufacturer.
  • Ready for tenderItem-by-item specification text for all layers, matching the tested assembly.
Technical data

All performance values at a glance

The values are taken from the test report. They apply to the laboratory test rig without flanking transmission; values in the building depend on the junctions.

System designation
BM 1.6.1 22 WF UDP
Build-up from the top
2x12,5 ST Tri/22 HFD UDP
Floor type
Concrete floor slab
Screed
Dry screed
Ceiling lining
none
Insulation board
2 × 12.5 mm PhoneStar ST Tri sound insulation boards, m’ = 36.3 kg/m²
Impact sound insulation board
22 mm wood fibre insulation boards, m’ = 5.1 kg/m²
Structure
160 mm reinforced concrete slab, m’ = 382 kg/m²
Weighted normalised impact sound pressure level
Ln,w (CI) = 54 (-1) dB
Weighted sound reduction index
Rw = 67 dB (C; Ctr = -2; -6 dB)
Mass per unit area
423.3 kg/m²
Total build-up thickness
207 mm
Use category
Coordinate with the manufacturer
Fire resistance from above
unclassified
Fire resistance from below
REI90
Test evidence
Test report 22-001793-PR01 PB D13-F03-04-de-01
Manufacturer
Wolf Bavaria GmbH, Heilsbronn

Good to know

Need a different assembly? If none of our tested assemblies fits, our technical application team will work with you and our partners to develop a bespoke assembly and have it tested.

On-site values depend on flanking paths, junctions and penetrations. On request, we can measure the sound insulation in the laboratory or directly on site.

Variants

The BM 1.6 system family compared

Same structural floor, different screed and ceiling lining options. For both values, a longer bar means better sound insulation: lower impact sound level, higher airborne sound insulation.

You will find all 55 floor assemblies, with filters and direct comparison, in the Assemblies overview →

Everything from a single source

Request design documents for this assembly

You will receive the complete package by email, tailored to this assembly. On request, our technical application team will contact you personally.

  • Test report 22-001793-PR01 PB D13-F03-04-de-01Cover sheet
  • ETA-20/0371 PhoneStar acoustic boards
  • Data sheet: PhoneStar ST Tri
  • Data sheet: Wolf wood fibre insulation board
  • Installation instructions for Wolf Bavaria systems
  • Specification text: Wolf system solutions, concrete floor slab
  • Personal consultationOur technical application team checks variants for your project
Markus Schramm, Wolf Bavaria, in productionMarkus Schramm as a cartoon character from the explainer video
“My team and I will be happy to help you personally with any technical questions. Please feel free to send us an enquiry.”

Markus SchrammM.Eng., Dipl.-Ing. (FH)
Head of Technical and Building Acoustics

Request documents

Assembly: BM 1.6.1 22 WF UDP