Measured in the laboratoryDry construction

Timber joist floor with dry screed and ceiling on battens

System designation BHG 1.6_Laminat

Build-up from the top 8 Laminat/2x15 Tri/20 HFD

Tested floor assembly on a timber joist floor. In the laboratory, the assembly achieves a weighted normalised impact sound pressure level of 59 dB and a weighted sound reduction index of 57 dB. The assembly is installed completely dry, with no drying time. On the underside, a ceiling lining on battens adds to the sound insulation.

Section drawing · dimensions in mm
59dB
Impact sound Ln,wCI = 1 dB · laboratory
57dB
Airborne sound RwLaboratory
388.5mm
Total build-upincluding the structural floor
DIN 4102-4
Fire resistance from belowfrom above: unclassified
Bestseller for concrete floor slabs
Wolf Bavaria system assembly

The assembly layer by layer

Section drawing and isometric view of the tested assembly BHG 1.6_Laminat, with all layer thicknesses. Select a layer in the drawing, the legend or the layer list to see its function.

Build-up height Impact sound Ln,w = 59 dBAirborne sound Rw = 57 dBDry screedValues according to the test report
Tip: use ↑ ↓ to step through the layers
ItemLayerThickness [mm]
In brief

Key facts at a glance

  • Tested: Impact sound Ln,w = 59 dB and airborne sound Rw = 57 dB in the laboratory, documented in the test report.
  • Dry installation: no drying time, so the following trades can start promptly.
  • 388.5 mm total build-up including the structural floor.
  • All documents free of charge: Section drawing, test report, specification text and data sheets as PDFs by email.

Request planning documents

Explainer video · 1:40

System assemblies explained in 100 seconds

Architect Tina designs, developer Thorsten needs the evidence, building physicist Patrick checks it. Markus Schramm shows why our system assemblies are already tested and how our technical application team supports you with your own assemblies.

Ask a technical question
Explainer video thumbnail, system assemblies: over 50 tested assemblies 1:40

The video is only loaded from YouTube when you play it.

For your design

What this assembly means for you

Designers, tradespeople and developers look at different details. Choose who you are.

Design
Installation
Build and buy
Cartoon figure of architects

Design

Architects

What do I need to know for design and tendering?

  • 388.5 mm total build-upIncluding the structural floor. Mass per unit area on request.
  • Fire resistanceFrom above unclassified, from below DIN 4102-4.
  • Ceiling liningBattens.
  • Use categoryA1–A3.
  • Ready for tenderItem-by-item specification text for all layers, matching the tested assembly.
Technical data

All performance values at a glance

The values are taken from the test report. They apply to the laboratory test rig without flanking transmission; values in the building depend on the junctions.

System designation
BHG 1.6_Laminat
Build-up from the top
8 Laminat/2x15 Tri/20 HFD
Floor type
Timber joist floor
Screed
Dry screed
Ceiling lining
Battens
Weighted normalised impact sound pressure level
Ln,w (CI) = 59 (1) dB
Weighted sound reduction index
Rw = 57 dB
Total build-up thickness
388.5 mm
Use category
A1–A3
Fire resistance from above
unclassified
Fire resistance from below
DIN 4102-4
Test evidence
Test report P-BA 92-2006
Manufacturer
Wolf Bavaria GmbH, Heilsbronn

Good to know

Need a different assembly? If none of our tested assemblies fits, our technical application team will work with you and our partners to develop a bespoke assembly and have it tested.

On-site values depend on flanking paths, junctions and penetrations. On request, we can measure the sound insulation in the laboratory or directly on site.

Load-bearing structure. The timber joists and the wood-based panel carry the structural loads. The bays, completely filled with porous fibrous insulation, damp the floor cavity and reduce resonances within the construction.

Variants

Similar assemblies: timber joist floor

Assemblies on the same floor type with comparable ratings. For impact sound, shorter bars mean a lower level; for airborne sound, longer bars mean more insulation.

You will find all 55 floor assemblies, with filters and direct comparison, in the Assemblies overview →

Everything from a single source

Request design documents for this assembly

You will receive the complete package by email, tailored to this assembly. On request, our technical application team will contact you personally.

  • Installation instructions for Wolf Bavaria systems
  • Wolf system solutions specification text: timber joist floor
  • Personal consultationOur technical application team checks variants for your project
Markus Schramm, Wolf Bavaria, in productionMarkus Schramm as a cartoon character from the explainer video
“My team and I will be happy to help you personally with any technical questions. Please feel free to send us an enquiry.”

Markus SchrammM.Eng., Dipl.-Ing. (FH)
Head of Technical and Building Acoustics

Request documents

Assembly: BHG 1.6_Laminat