Measured in the laboratoryDry constructionUnderfloor heating integrated

Timber joist floor with dry screed, underfloor heating and suspended ceiling

System designation BHG. 1.10 20mm, Hugo, PowerFloor + DHG H 1.2 ST TRI

Build-up from the top 18 GF/20 WPF ÖKO/2x15 Tri/HFD 20 /80 Splitt geb.

Tested floor build-up on a timber joist floor. In the laboratory, the assembly achieves a weighted normalised impact sound pressure level of 32 dB and a weighted sound reduction index of 83 dB. The assembly is installed completely dry, with no drying time. On the underside, a ceiling lining (TPS25 profiles with clips) adds to the sound insulation.

Section drawing · dimensions in mm
32dB
Impact sound Ln,wCI = 2 dB · laboratory
83dB
Airborne sound RwLaboratory
484mm
Total build-upincluding the structural floor
278.8kg/m²
Mass per unit areaTotal build-up
REI45
Fire resistance from belowfrom above: F30-B
Bestseller for concrete floor slabs
Wolf Bavaria system assembly

The assembly layer by layer

Section drawing and isometric view of the tested assembly BHG. 1.10 20mm, Hugo, PowerFloor + DHG H 1.2 ST TRI, with all layer thicknesses. Select a layer in the drawing, the legend or the layer list to see its function.

Build-up height Impact sound Ln,w = 32 dBAirborne sound Rw = 83 dBDry screedValues according to the test report
Tip: use ↑ ↓ to step through the layers
ItemLayerThickness [mm]
In brief

Key facts at a glance

  • Tested: Impact sound Ln,w = 32 dB and airborne sound Rw = 83 dB in the laboratory, documented in the test report.
  • Dry installation: no drying time, so the following trades can start promptly.
  • 484 mm total build-up including the structural floor.
  • All documents free of charge: Section drawing, test report, specification text and data sheets as PDFs by email.

Request planning documents

Explainer video · 1:40

System assemblies explained in 100 seconds

Architect Tina designs, developer Thorsten needs the evidence, building physicist Patrick checks it. Markus Schramm shows why our system assemblies are already tested and how our technical application team supports you with your own assemblies.

Ask a technical question
Explainer video thumbnail, system assemblies: over 50 tested assemblies 1:40

The video is only loaded from YouTube when you play it.

For your design

What this assembly means for you

Designers, tradespeople and developers look at different details. Choose who you are.

Design
Installation
Build and buy
Cartoon figure of architects

Design

Architects

What do I need to know for design and tendering?

  • 484 mm total build-upIncluding the structural floor. Mass per unit area 278.8 kg/m².
  • Fire resistanceFrom above F30-B, from below REI45.
  • Ceiling liningTPS25 profiles with clips.
  • Use categoryA1–B2.
  • Ready for tenderItem-by-item specification text for all layers, matching the tested assembly.
Technical data

All performance values at a glance

The values are taken from the test report. They apply to the laboratory test rig without flanking transmission; values in the building depend on the junctions.

System designation
BHG. 1.10 20mm, Hugo, PowerFloor + DHG H 1.2 ST TRI
Build-up from the top
18 GF/20 WPF ÖKO/2x15 Tri/HFD 20 /80 Splitt geb.
Floor type
Timber joist floor
Screed
Dry screed
Ceiling lining
TPS25 profiles with clips
Underfloor heating
integrated in the assembly
BHG 1.10
20 mm; Hugo; ÖKO / ÖKO PLUS + DHG H 1.2
ST TRI screed
18 mm Wolf Hugo GF gypsum fibre dry screed board, m’ = 22.1 kg/m²
Insulation board
24 mm wood fibre insulation boards, m’ = 6.4 kg/m²
Insulation board
2 × 15 mm PhoneStar Tri sound insulation boards, m’ = 37.8 kg/m²
Insulation board
20 mm wood fibre insulation boards, m’ = 3.2 kg/m²
Fill
80 mm bonded grit fill, m’ = 131.9 kg/m²
Sheathing
22 mm wood-based panels, m’ = 13.3 kg/m²
Structure
240 mm structural solid timber, e = 508 mm
Insulation
2 × 120 mm mineral wool insulation, ρ = 20.6 kg/m³
Substructure
25 mm sheet steel profiles with clips, e = 417 mm
Ceiling lining board
12.5 mm PhoneStar ST Tri sound insulation boards, m’ = 17.9 kg/m²
Ceiling lining board
12.5 mm fire-rated plasterboard, m’ = 12.9 kg/m²
Weighted normalised impact sound pressure level
Ln,w (CI) = 32 (2) dB
Weighted sound reduction index
Rw = 83 dB (C; Ctr = -3; -9 dB)
Mass per unit area
278.8 kg/m²
Total build-up thickness
484 mm
Use category
A1–B2
Fire resistance from above
F30-B
Fire resistance from below
REI45
Test evidence
Test report 17-001670-PR01 PB X09-F03-04-de-01_PB01
Manufacturer
Wolf Bavaria GmbH, Heilsbronn

Good to know

Need a different assembly? If none of our tested assemblies fits, our technical application team will work with you and our partners to develop a bespoke assembly and have it tested.

On-site values depend on flanking paths, junctions and penetrations. On request, we can measure the sound insulation in the laboratory or directly on site.

Load-bearing structure. The timber joists and the wood-based panel carry the structural loads. The bays, completely filled with porous fibrous insulation, damp the floor cavity and reduce resonances within the construction.

Ceiling lining with PhoneStar. Compared with a ceiling lining clad with plasterboard alone, the additional PhoneStar layer improves the normalised impact sound pressure level in the laboratory by up to 15 dB. Even higher sound insulation values can be achieved with a resiliently suspended ceiling, allowing a further improvement of 10 dB.

For this type of ceiling lining, fire resistance under fire exposure from below was also tested. A fire resistance of 45 minutes (REI 45) was achieved. On the basis of this test, a general building authority test certificate (abP) was issued.

Particularly effective at low frequencies. In timber joist floors with deep, insulated cavities in particular, the ceiling lining has especially high acoustic potential. Combined with a resilient suspension, it forms a largely decoupled second leaf. The additional PhoneStar board, heavy yet flexible, increases the mass of this leaf and improves the mass-spring-mass system of the entire floor construction. The large distance between the leaves is particularly beneficial in the critical low-frequency range.

Laboratory measurements confirm its effectiveness: the additional PhoneStar layer on the resiliently suspended ceiling improved the extended rating value (Ln,w + CI,50-2500) in a direct comparison assembly by 9 dB. The impact sound components between 50 and 100 Hz, which are particularly disturbing in timber joist floors, are also attenuated much more effectively.

Everything from a single source

Request design documents for this assembly

You will receive the complete package by email, tailored to this assembly. On request, our technical application team will contact you personally.

  • Test report 17-001670-PR01 PB X09-F03-04-de-01_PB01Cover sheet
  • ETA-20/0371 PhoneStar acoustic boards
  • Data sheet: PhoneStar ST Tri
  • PhoneStar Tri data sheet
  • Data sheet Wolf HUGO 18 and 23 mm
  • PowerFloor Light data sheet
  • Data sheet: Wolf wood fibre insulation board
  • Limestone grit fill data sheet
  • Installation instructions for Wolf Bavaria systems
  • Wolf HUGO installation guide
  • Wolf system solutions specification text: timber joist floor
  • Expert opinion, test series 17-001670
  • Personal consultationOur technical application team checks variants for your project
Markus Schramm, Wolf Bavaria, in productionMarkus Schramm as a cartoon character from the explainer video
“My team and I will be happy to help you personally with any technical questions. Please feel free to send us an enquiry.”

Markus SchrammM.Eng., Dipl.-Ing. (FH)
Head of Technical and Building Acoustics

Request documents

Assembly: BHG. 1.10 20mm, Hugo, PowerFloor + DHG H 1.2 ST TRI