Solid timber or engineered wood floor with dry screed
System designation BHB 1.6 mm MiWo
Build-up from the top 2x15 Tri/20 MiWo
Tested floor assembly on a solid timber or engineered wood floor. In the laboratory, the assembly achieves a weighted normalised impact sound pressure level of 56 dB and a weighted sound reduction index of 54 dB. The assembly is installed entirely dry, with no drying time. The values are achieved without a ceiling lining, so the timber soffit can remain exposed.
The assembly layer by layer
Section drawing and isometric view of the tested assembly BHB 1.6 mm MiWo, with all layer thicknesses. Select a layer in the drawing, the legend or the layer list to see its function.
| Item | Layer | Thickness [mm] |
|---|
Key facts at a glance
- Tested: Impact sound Ln,w = 56 dB and airborne sound Rw = 54 dB in the laboratory, documented in the test report.
- Dry installation: no drying time, so the following trades can start promptly.
- 190 mm total build-up including the structural floor.
- All documents free of charge: Section drawing, test report, specification text and data sheets as PDFs by email.
System assemblies explained in 100 seconds
Architect Tina designs, developer Thorsten needs the evidence, building physicist Patrick checks it. Markus Schramm shows why our system assemblies are already tested and how our technical application team supports you with your own assemblies.
Ask a technical question →
1:40
The video is only loaded from YouTube when you play it.
What this assembly means for you
Designers, tradespeople and developers look at different details. Choose who you are.
Design
Architects
What do I need to know for design and tendering?
- 190 mm total build-upIncluding the structural floor. Mass per unit area 110.2 kg/m².
- Fire resistanceFrom above without classification, from below charring to EC5.
- Ceiling liningNone, the floor soffit remains exposed.
- Use categoryConsult the manufacturer.
- Ready for tenderItem-by-item specification text for all layers, matching the tested assembly.
Design
Designers and specialist consultants
Which values do I need for structural design and detailed design?
- Layer sequence from the top2x15 Tri/20 MiWo.
- Masses for load calculationMass per unit area 110.2 kg/m².
- Fire resistanceFrom above without classification, from below charring to EC5.
- Clarify deviationsDifferent floor thickness, finish or use? We will check with you whether the evidence can be transferred.
Design
Building physicists and acousticians
How reliable are the performance values?
- Ln,w = 56 dB, CI = 1 dBRw = 54 dB (C = -2 dB, Ctr = -8 dB), measured in the laboratory.
- EvidenceTest report 18-001770-PR02 PB X27-F03-04-de-01. The values apply to laboratory conditions without flanking transmission.
- Mass per unit area110.2 kg/m² for the total build-up.
Installation
Carpenter
What does the assembly mean for installation?
- Completely dryNo water in the assembly, no drying time. Work can continue immediately after installation.
- Clear layer sequence2x15 Tri/20 MiWo, from top to bottom.
- Edge detail with SchalliThe PhoneStar Schalli perimeter edge strip prevents rigid contact with walls and penetrations. With softer mineral fibre insulation layers, we always recommend edge and floor stabilisation with PhoneStar Schalli.
- Everything from a single sourceThe components come from Wolf Bavaria as a matched system, with installation instructions and a personal contact.
Installation
Timber construction companies
How does the assembly fit into my building?
- No moisture in timber constructionThe floor assembly is dry. This protects the timber structure and your construction schedule.
- Exposed timber stays exposedThe performance values are achieved without a ceiling lining, so the timber soffit can remain exposed.
- Tested, not estimatedWith test report 18-001770-PR02 PB X27-F03-04-de-01, you can demonstrate the sound insulation to the client and the designer.
- One partner for the whole floorSound insulation, dry screed and accessories come from a single source, fully coordinated.
Installation
Modular and prefab house builders
Is the assembly suitable for prefabrication?
- Dry in the factoryNo wet screed, no drying time. The floor fits into the timed production cycles in the factory hall.
- Predictable build-up height190 mm total build-up including the structural floor.
- Keeping an eye on weightMass per unit area 110.2 kg/m². We are happy to calculate variants for transport and installation with you.
- RepeatableOne tested system assembly for your series, with fixed components and a dedicated contact.
Installation
Master screed installer
What should I bear in mind with the screed?
- Dry instead of wetDry screed without the drying times of a cement screed.
- Layer sequence2x15 Tri/20 MiWo.
- Edge detail with SchalliThe PhoneStar Schalli perimeter edge strip prevents rigid contact with walls and penetrations. With softer mineral fibre insulation layers, we always recommend edge and floor stabilisation with PhoneStar Schalli.
- Choosing the floor coveringWe are happy to discuss with you in advance which floor covering suits your use.
Installation
Heating installer
What about underfloor heating?
- Planning for underfloor heatingThis assembly has been tested without underfloor heating. We will check with you whether PowerFloor can be integrated into the assembly.
- Design support includedFor PowerFloor, we provide you with a laying plan and a materials list.
Build and buy
Developer
What does the assembly deliver for my project?
- Verified sound insulationLn,w 56 dB and Rw 54 dB, verified by test report 18-001770-PR02 PB X27-F03-04-de-01.
- Short construction timeDry assembly with no drying time, so the following trades can start promptly.
- One point of contactMaterials and advice from a single source, from quotation to site.
Build and buy
Building owners
What do I gain as a resident?
- Peace and quiet between floorsFootsteps and voices from the neighbouring flat are significantly reduced.
- No construction moistureThe assembly goes into the building dry, with no water and no drying time.
- Natural materialsPhoneStar consists of quartz sand and honeycomb cardboard.
- Personal consultationOur field sales team advises you directly on your assembly.
Build and buy
Purchasing at builders’ merchants
What do I need for my product range and customer advice?
- One system, one supplierAll components of the assembly come from Wolf Bavaria and are designed to work together.
- Arguments for your customersTested values, Ln,w 56 dB and Rw 54 dB.
- Product data at handData sheets and installation guides for advice and quotations.
- Direct lineOur sales team supports you with your customers’ enquiries and projects.
All performance values at a glance
The values are taken from the test report. They apply to the laboratory test rig without flanking transmission; values in the building depend on the junctions.
- System designation
- BHB 1.6 mm MiWo
- Build-up from the top
- 2x15 Tri/20 MiWo
- Floor type
- Solid timber or engineered wood floor
- Screed
- Dry screed
- Ceiling lining
- none
- Screed
- 2 × 15 mm PhoneStar Tri acoustic boards, m’ = 39.0 kg/m²
- Insulation board
- 20 mm Wolf MiWo stone wool screed insulation boards, m’ = 3.8 kg/m²
- Structural slab
- 140 mm CLT elements, m’ = 67.4 kg/m²
- Weighted normalised impact sound pressure level
- Ln,w (CI) = 56 (1) dB
- Weighted sound reduction index
- Rw = 54 dB (C; Ctr = -2; -8 dB)
- Mass per unit area
- 110.2 kg/m²
- Total build-up thickness
- 190 mm
- Use category
- Coordinate with the manufacturer
- Fire resistance from above
- unclassified
- Fire resistance from below
- Charring to EC5
- Test evidence
- Test report 18-001770-PR02 PB X27-F03-04-de-01
- Manufacturer
- Wolf Bavaria GmbH, Heilsbronn
Good to know
Need a different assembly? If none of our tested assemblies fits, our technical application team will work with you and our partners to develop a bespoke assembly and have it tested.
On-site values depend on flanking paths, junctions and penetrations. On request, we can measure the sound insulation in the laboratory or directly on site.
Similar assemblies: solid timber or engineered wood floor
Assemblies on the same floor type with comparable ratings. For impact sound, shorter bars mean a lower level; for airborne sound, longer bars mean more insulation.
You will find all 55 floor assemblies, with filters and direct comparison, in the Assemblies overview →
Dry floor assemblies in practice
PhoneStar and PowerFloor in use: projects in which our partners have combined sound insulation and underfloor heating in the floor.
New build · circularStraßenverkehrsamt Kreis Viersen (road traffic office)
zebo Fußbodenbau laid around 7,000 m² of flooring with PhoneStar impact sound insulation, combined with underfloor heating and designed for future dismantling.
Loft conversion in an existing buildingFarmhouse in the Allgäu
Dry floor assembly with PhoneStar and PowerFloor underfloor heating on an old floorboard floor, installed by the owners themselves.
Prefabricated house from the factoryKeitel-Haus, residential building in Goldbach
Wall and floor elements with PhoneStrip and PhoneStar, prefabricated in the factory. The result has been measured on site.
Prefabricated timber houseKurmann Holzbau, Glücksburg
15 residential units in prefabricated timber construction. With PhoneStar and PhoneStrip, the separating wall and separating floor meet the increased requirements.
Request design documents for this assembly
You will receive the complete package by email, tailored to this assembly. On request, our technical application team will contact you personally.
- Test report 18-001770-PR02 PB X27-F03-04-de-01Cover sheet
- ETA-20/0371 PhoneStar acoustic boards
- PhoneStar Tri data sheet
- Wolf MiWo data sheet
- Installation instructions for Wolf Bavaria systems
- Wolf system solutions specification text: solid timber floor
- Expert opinion on test series 18-001770
- Personal consultationOur technical application team checks variants for your project


“My team and I will be happy to help you personally with any technical questions. Please feel free to send us an enquiry.”
Markus SchrammM.Eng., Dipl.-Ing. (FH)
Head of Technical and Building Acoustics
Request documents
Assembly: BHB 1.6 mm MiWo