BestsellerMeasured in the laboratoryDry constructionUnderfloor heating integrated

Solid timber floor with dry screed and underfloor heating

System designation BHB 1.10 20 mm MiWo, Power Floor, Hugo

Build-up from the top 18 GF/20 WPF Light/2x15 Tri/20 MiWo/80 Splitt geb.

Dry, heatable floor assembly on 140 mm CLT. A floating gypsum fibre dry screed, two PhoneStar layers and a heavy grit weighting layer provide high sound insulation without a ceiling lining. The timber soffit of the floor remains exposed.

Section drawing · dimensions in mm
43dB
Impact sound Ln,wCI = 0 dB · laboratory
66dB
Airborne sound RwLaboratory
168mm
Floor build-upon 140 mm CLT
308mm
Total build-upincluding the structural floor
263.4kg/m²
Mass per unit areaTotal build-up
Charring to EC5
Fire resistance from belowfrom above: F30-B
Bestseller for concrete floor slabs
Wolf Bavaria system assembly

The assembly layer by layer

Section drawing and isometric view of the tested assembly BHB 1.10 20 mm MiWo, Power Floor, Hugo, with all layer thicknesses. Select a layer in the drawing, the legend or the layer list to see its function.

Total thickness incl. structural floor Impact sound Ln,w = 43 dBAirborne sound Rw = 66 dBDry screedUnderfloor heating integratedValues according to the test report
Tip: use ↑ ↓ to step through the layers
ItemLayerThickness [mm]
In brief

Key facts at a glance

  • Tested: Impact sound Ln,w = 43 dB and airborne sound Rw = 66 dB in the laboratory, documented in the test report.
  • Dry installation: no drying time, so the following trades can start promptly.
  • 308 mm total build-up including the structural floor, with integrated underfloor heating.
  • All documents free of charge: Section drawing, test report, specification text and data sheets as PDFs by email.

Request planning documents

Explainer video · 1:40

System assemblies explained in 100 seconds

Architect Tina designs, developer Thorsten needs the evidence, building physicist Patrick checks it. Markus Schramm shows why our system assemblies are already tested and how our technical application team supports you with your own assemblies.

Ask a technical question
Explainer video thumbnail, system assemblies: over 50 tested assemblies 1:40

The video is only loaded from YouTube when you play it.

For your design

What this assembly means for you

Designers, tradespeople and building owners look at different details. Choose who you are.

Design
Installation
Build and buy
Cartoon figure of architects

Design

Architects

What do I need to know for design and tendering?

  • 168 mm floor build-upOn 140 mm cross-laminated timber, the total build-up thickness is 308 mm.
  • Exposed timber ceilingThe values are achieved without a ceiling lining, so the CLT soffit can remain exposed.
  • Underfloor heating includedPowerFloor Light is integrated into the assembly and brings no additional construction moisture into the building.
  • Use category A1 to B1For other uses, we will agree the design loads and assembly with you.
Technical data

All performance values at a glance

The values are taken from the test report. They apply to the laboratory test rig without flanking transmission; values in the building depend on the junctions.

System designation
BHB 1.10 20 mm MiWo, Power Floor, Hugo
Floor type
Solid timber floor, CLT 140 mm
Screed
Dry screed, 18 mm Wolf HUGO GF gypsum fibre dry screed boardm′ = 22.7 kg/m²
Underfloor heating
Wolf PowerFloor Light, 20 mm
Sound insulation boards
PhoneStar Tri, 2 × 15 mm
Impact sound insulation
Wolf MiWo mineral fibre impact sound insulation board, 20 mm
Weighting layer
80 mm grit fill, cement-bondedm′ = 129.1 kg/m²
Ceiling lining
none, optionally resiliently suspended
Weighted normalised impact sound pressure level
Ln,w (CI) = 43 (0) dB
Weighted sound reduction index
Rw = 66 dB
Mass per unit area
263.4 kg/m²
Total build-up thickness
308 mmof which floor build-up 168 mm
Build-up from the top
18 GF/20 WPF Light/2x15 Tri/20 MiWo/80 Splitt geb.
Fire resistance from above
F30-B
Fire resistance from below
Charring to EC5
Use category
A1 to B1
Test evidence
Test report 18-001770-PR02 PB X15-F03-04-de-01
Manufacturer
Wolf Bavaria GmbH, Heilsbronn

Good to know

Need more sound insulation? With a resiliently suspended ceiling, the BHB 1.10 system family achieves Ln,w = 27 dB and Rw = 79 dB.

A pronounced effect below 100 Hz generally requires suspension heights of more than 120 mm. We plan suspension height, spring effect, lining mass and cavity insulation together with you.

If rigid bonding of the fill is essential, a layer of PhoneStar 25 beneath the fill can significantly reduce the adverse coupling effect.

Variants

The BHB 1.10 system family compared

Same solid timber floor, different screed and ceiling lining options. For both values, a longer bar means better sound insulation: lower impact sound level, higher airborne sound insulation.

You will find all 55 floor assemblies, with filters and direct comparison, in the Assemblies overview →

Everything from a single source

Request design documents for this assembly

You will receive the complete package by email, tailored to this assembly. On request, our technical application team will contact you personally.

  • Specification textDescribed item by item, ready to copy into your bill of quantities
  • Test reportAcoustic test 18-001770-PR02 PB X15-F03-04-de-01
  • ETA-20/0371European Technical Assessment for PhoneStar sound insulation boards
  • Data sheets and installation instructionsAll components of the assembly, designed to work together
  • Section drawingGraphic of the assembly for your design documents
  • Personal consultationOur technical application team checks variants for your project
Markus Schramm, Wolf Bavaria, in productionMarkus Schramm as a cartoon character from the explainer video
“My team and I will be happy to help you personally with any technical questions. Please feel free to send us an enquiry.”

Markus SchrammM.Eng., Dipl.-Ing. (FH)
Head of Technical and Building Acoustics

Request documents

Assembly: BHB 1.10 20 mm MiWo, Power Floor, Hugo