Solid timber floor with dry screed and underfloor heating
System designation BHB 1.10 20 mm MiWo, Power Floor, Hugo
Build-up from the top 18 GF/20 WPF Light/2x15 Tri/20 MiWo/80 Splitt geb.
Dry, heatable floor assembly on 140 mm CLT. A floating gypsum fibre dry screed, two PhoneStar layers and a heavy grit weighting layer provide high sound insulation without a ceiling lining. The timber soffit of the floor remains exposed.
The assembly layer by layer
Section drawing and isometric view of the tested assembly BHB 1.10 20 mm MiWo, Power Floor, Hugo, with all layer thicknesses. Select a layer in the drawing, the legend or the layer list to see its function.
| Item | Layer | Thickness [mm] |
|---|
Key facts at a glance
- Tested: Impact sound Ln,w = 43 dB and airborne sound Rw = 66 dB in the laboratory, documented in the test report.
- Dry installation: no drying time, so the following trades can start promptly.
- 308 mm total build-up including the structural floor, with integrated underfloor heating.
- All documents free of charge: Section drawing, test report, specification text and data sheets as PDFs by email.
System assemblies explained in 100 seconds
Architect Tina designs, developer Thorsten needs the evidence, building physicist Patrick checks it. Markus Schramm shows why our system assemblies are already tested and how our technical application team supports you with your own assemblies.
Ask a technical question →
1:40
The video is only loaded from YouTube when you play it.
What this assembly means for you
Designers, tradespeople and building owners look at different details. Choose who you are.
Design
Architects
What do I need to know for design and tendering?
- 168 mm floor build-upOn 140 mm cross-laminated timber, the total build-up thickness is 308 mm.
- Exposed timber ceilingThe values are achieved without a ceiling lining, so the CLT soffit can remain exposed.
- Underfloor heating includedPowerFloor Light is integrated into the assembly and brings no additional construction moisture into the building.
- Use category A1 to B1For other uses, we will agree the design loads and assembly with you.
Design
Designers and specialist consultants
Which values do I need for structural design and detailed design?
- Masses for load calculationTotal build-up 263.4 kg/m², of which grit weighting 129.1 kg/m² and dry screed 22.7 kg/m².
- Heights for detailed design168 mm floor build-up above the structural floor, 308 mm total build-up with 140 mm CLT.
- Ready for tenderItem-by-item specification text for all layers, matching the tested assembly.
- Clarify deviationsDifferent floor thickness, finish or use? We will check with you whether the evidence can be transferred.
Design
Building physicists and acousticians
How reliable are the performance values?
- Ln,w = 43 dB, CI = 0 dBRw = 66 dB, measured in the laboratory. Test report 18-001770-PR02 PB X15-F03-04-de-01.
- Mass-spring-massGrit weighting m′ = 129.1 kg/m² and dry screed m′ = 22.7 kg/m², separated by a mineral fibre impact sound insulation board.
- Bonding of the fillThe test assembly uses cement-bonded grit. Comparative measurements show a difference of 4 to 5 dB between rigid bonding and acoustically more favourable bonding.
- Standard referenceA very similar construction is given in Table 32 of the draft standard E DIN 4109-33:2026-09, there without PowerFloor and with loose fill.
Installation
Carpenter
What does the assembly mean for installation?
- Completely dryNo water in timber construction, no drying time. Work can continue immediately after installation.
- Clear layer sequenceGrit fill 80 mm, Wolf MiWo 20 mm, PhoneStar Tri 2 × 15 mm, PowerFloor Light 20 mm and HUGO GF 18 mm, from bottom to top.
- Clean edgesA perimeter 20 mm PhoneStar Schalli prevents rigid edge contact with walls and penetrations.
- Everything from a single sourceBoards, insulation, underfloor heating and accessories come from Wolf Bavaria as a matched system, with installation instructions and a personal contact.
Installation
Timber construction companies
How does the assembly fit into my timber building?
- No moisture in the CLT floorThe entire floor build-up is dry. This protects the solid timber floor and your construction schedule.
- Exposed timber stays exposedThe sound insulation is provided above the floor. The CLT soffit can remain exposed.
- Tested, not estimatedTest report 18-001770-PR02 PB X15-F03-04-de-01 lets you demonstrate the acoustic performance to clients and designers.
- One partner for the whole floorSound insulation, dry screed and underfloor heating come from a single source, fully coordinated.
Installation
Modular and prefab house builders
Is the assembly suitable for prefabrication?
- Dry in the factoryNo wet screed, no drying time. The floor fits into the timed production cycles in the factory hall.
- Predictable build-up height168 mm floor build-up above the structural floor, including underfloor heating.
- Keeping an eye on weightThe grit weighting layer adds 129.1 kg/m². We are happy to calculate variants for transport and installation with you.
- RepeatableOne tested system assembly for your series, with fixed components and a dedicated contact.
Installation
Master screed installer
What should I bear in mind with dry screed?
- Dry instead of wet18 mm Wolf HUGO GF gypsum fibre dry screed board, without the drying times of a cement screed.
- Solid substrateBeneath these are PowerFloor Light and two layers of PhoneStar Tri as a heavy, level load distribution layer.
- Edge joint as a systemPhoneStar Schalli as a perimeter edge strip acoustically separates the screed from the walls.
- Choosing the floor coveringWe are happy to discuss with you in advance which floor covering suits your use.
Installation
Heating installer
How is the underfloor heating constructed?
- PowerFloor Light, 20 mmHoneycomb board with milled pipe channels and aluminium heat-conducting plate, directly beneath the dry screed.
- Fast responseLow mass above the pipes ensures short response times for heating and cooling.
- Laid dryNo heated screed, no initial heating-up. The system brings no construction moisture into the building.
- Design support includedInstallation layout and heating load calculation are available from us on request.
Build and buy
Developer
What does the assembly deliver for my project?
- Verified sound insulationLn,w 43 dB and Rw 66 dB, verified by test report. This gives you certainty towards your buyers.
- Short construction timeDry assembly with no drying times, so the following trades can start promptly.
- Added value for the flatIntegrated underfloor heating, exposed timber floor: two strong selling points.
- One point of contactMaterials and advice from a single source, from quotation to site.
Build and buy
Building owners
What do I gain as a resident?
- Peace and quiet between floorsFootsteps and voices from the neighbouring flat are significantly reduced.
- Warm feetThe underfloor heating is integrated into the floor and responds quickly.
- Timber you can seeThe solid timber floor remains exposed from below and defines the character of the room.
- Natural materialsPhoneStar consists of sand and honeycomb cardboard, and the assembly introduces no construction moisture.
Build and buy
Purchasing at builders’ merchants
What do I need for my product range and customer advice?
- One system, one supplierAll components of the assembly come from Wolf Bavaria and are designed to work together.
- Arguments for your customersTested values, Ln,w 43 dB and Rw 66 dB, and a top seller among the solid timber assemblies.
- Product data at handData sheets and installation guides for advice and quotations.
- Direct lineOur sales team supports you with your customers’ enquiries and projects.
All performance values at a glance
The values are taken from the test report. They apply to the laboratory test rig without flanking transmission; values in the building depend on the junctions.
- System designation
- BHB 1.10 20 mm MiWo, Power Floor, Hugo
- Floor type
- Solid timber floor, CLT 140 mm
- Screed
- Dry screed, 18 mm Wolf HUGO GF gypsum fibre dry screed boardm′ = 22.7 kg/m²
- Underfloor heating
- Wolf PowerFloor Light, 20 mm
- Sound insulation boards
- PhoneStar Tri, 2 × 15 mm
- Impact sound insulation
- Wolf MiWo mineral fibre impact sound insulation board, 20 mm
- Weighting layer
- 80 mm grit fill, cement-bondedm′ = 129.1 kg/m²
- Ceiling lining
- none, optionally resiliently suspended
- Weighted normalised impact sound pressure level
- Ln,w (CI) = 43 (0) dB
- Weighted sound reduction index
- Rw = 66 dB
- Mass per unit area
- 263.4 kg/m²
- Total build-up thickness
- 308 mmof which floor build-up 168 mm
- Build-up from the top
- 18 GF/20 WPF Light/2x15 Tri/20 MiWo/80 Splitt geb.
- Fire resistance from above
- F30-B
- Fire resistance from below
- Charring to EC5
- Use category
- A1 to B1
- Test evidence
- Test report 18-001770-PR02 PB X15-F03-04-de-01
- Manufacturer
- Wolf Bavaria GmbH, Heilsbronn
Good to know
Need more sound insulation? With a resiliently suspended ceiling, the BHB 1.10 system family achieves Ln,w = 27 dB and Rw = 79 dB.
A pronounced effect below 100 Hz generally requires suspension heights of more than 120 mm. We plan suspension height, spring effect, lining mass and cavity insulation together with you.
If rigid bonding of the fill is essential, a layer of PhoneStar 25 beneath the fill can significantly reduce the adverse coupling effect.
The BHB 1.10 system family compared
Same solid timber floor, different screed and ceiling lining options. For both values, a longer bar means better sound insulation: lower impact sound level, higher airborne sound insulation.
You will find all 55 floor assemblies, with filters and direct comparison, in the Assemblies overview →
Dry floor assemblies in practice
PhoneStar and PowerFloor in use: projects in which our partners have combined sound insulation and underfloor heating in the floor.
New build · circularStraßenverkehrsamt Kreis Viersen (road traffic office)
zebo Fußbodenbau laid around 7,000 m² of flooring with PhoneStar impact sound insulation, combined with underfloor heating and designed for future dismantling.
Loft conversion in an existing buildingFarmhouse in the Allgäu
Dry floor assembly with PhoneStar and PowerFloor underfloor heating on an old floorboard floor, installed by the owners themselves.
Prefabricated house from the factoryKeitel-Haus, residential building in Goldbach
Wall and floor elements with PhoneStrip and PhoneStar, prefabricated in the factory. The result has been measured on site.
Prefabricated timber houseKurmann Holzbau, Glücksburg
15 residential units in prefabricated timber construction. With PhoneStar and PhoneStrip, the separating wall and separating floor meet the increased requirements.
Request design documents for this assembly
You will receive the complete package by email, tailored to this assembly. On request, our technical application team will contact you personally.
- Specification textDescribed item by item, ready to copy into your bill of quantities
- Test reportAcoustic test 18-001770-PR02 PB X15-F03-04-de-01
- ETA-20/0371European Technical Assessment for PhoneStar sound insulation boards
- Data sheets and installation instructionsAll components of the assembly, designed to work together
- Section drawingGraphic of the assembly for your design documents
- Personal consultationOur technical application team checks variants for your project


“My team and I will be happy to help you personally with any technical questions. Please feel free to send us an enquiry.”
Markus SchrammM.Eng., Dipl.-Ing. (FH)
Head of Technical and Building Acoustics
Request documents
Assembly: BHB 1.10 20 mm MiWo, Power Floor, Hugo