Measured in the laboratoryDry construction

Solid timber or engineered wood floor with dry screed and suspended ceiling

System designation BHB 1.10 20 mm MiWo + DHB M 1.3 ST Tri

Build-up from the top 2x15 Tri/20 MiWo/80 Splitt geb.

Tested floor build-up on a solid timber or engineered wood floor. In the laboratory, the assembly achieves a weighted normalised impact sound pressure level of 27 dB and a weighted sound reduction index of 79 dB. The assembly is installed completely dry, with no drying time. On the underside, a ceiling lining (TPS25 profiles with clips) adds to the sound insulation.

Section drawing · dimensions in mm
27dB
Impact sound Ln,wCI = 4 dB · laboratory
79dB
Airborne sound RwLaboratory
380mm
Total build-upincluding the structural floor
273.7kg/m²
Mass per unit areaTotal build-up
REI45
Fire resistance from belowfrom above: unclassified
Bestseller for concrete floor slabs
Wolf Bavaria system assembly

The assembly layer by layer

Section drawing and isometric view of the tested assembly BHB 1.10 20 mm MiWo + DHB M 1.3 ST Tri, with all layer thicknesses. Select a layer in the drawing, the legend or the layer list to see its function.

Build-up height Impact sound Ln,w = 27 dBAirborne sound Rw = 79 dBDry screedValues according to the test report
Tip: use ↑ ↓ to step through the layers
ItemLayerThickness [mm]
In brief

Key facts at a glance

  • Tested: Impact sound Ln,w = 27 dB and airborne sound Rw = 79 dB in the laboratory, documented in the test report.
  • Dry installation: no drying time, so the following trades can start promptly.
  • 380 mm total build-up including the structural floor.
  • All documents free of charge: Section drawing, test report, specification text and data sheets as PDFs by email.

Request planning documents

Explainer video · 1:40

System assemblies explained in 100 seconds

Architect Tina designs, developer Thorsten needs the evidence, building physicist Patrick checks it. Markus Schramm shows why our system assemblies are already tested and how our technical application team supports you with your own assemblies.

Ask a technical question
Explainer video thumbnail, system assemblies: over 50 tested assemblies 1:40

The video is only loaded from YouTube when you play it.

For your design

What this assembly means for you

Designers, tradespeople and developers look at different details. Choose who you are.

Design
Installation
Build and buy
Cartoon figure of architects

Design

Architects

What do I need to know for design and tendering?

  • 380 mm total build-upIncluding the structural floor. Mass per unit area 273.7 kg/m².
  • Fire resistanceFrom above: no classification; from below: REI45.
  • Ceiling liningTPS25 profiles with clips.
  • Use categoryConsult the manufacturer.
  • Ready for tenderItem-by-item specification text for all layers, matching the tested assembly.
Technical data

All performance values at a glance

The values are taken from the test report. They apply to the laboratory test rig without flanking transmission; values in the building depend on the junctions.

System designation
BHB 1.10 20 mm MiWo + DHB M 1.3 ST Tri
Build-up from the top
2x15 Tri/20 MiWo/80 Splitt geb.
Floor type
Solid timber or engineered wood floor
Screed
Dry screed
Ceiling lining
TPS25 profiles with clips
Screed
2 × 15 mm PhoneStar Tri acoustic boards, m’ = 39.0 kg/m²
Insulation board
20 mm Wolf MiWo stone wool screed insulation boards, m’ = 3.8 kg/m²
Weighting layer
80 mm bonded grit fill, m’ = 129.1 kg/m²
Structural slab
140 mm CLT elements, m’ = 67.4 kg/m²
Cavity insulation
40 mm Wolf MiWo mineral wool, ρ = 14.8 kg/m³
Substructure
60 mm battens, e = 312 mm
Substructure
25 mm sheet steel profiles with clips, e = 312 mm
Ceiling lining board
12.5 mm PhoneStar ST Tri acoustic boards, m’ = 19.0 kg/m²
Ceiling lining board
12.5 mm plasterboard, m’ = 9.1 kg/m²
Weighted normalised impact sound pressure level
Ln,w (CI) = 27 (4) dB
Weighted sound reduction index
Rw = 79 dB (C; Ctr = -5; -13 dB)
Mass per unit area
273.7 kg/m²
Total build-up thickness
380 mm
Use category
Coordinate with the manufacturer
Fire resistance from above
unclassified
Fire resistance from below
REI45
Test evidence
Test report 18-001770-PR02 PB X23-F03-04-de-01
Manufacturer
Wolf Bavaria GmbH, Heilsbronn

Good to know

Need a different assembly? If none of our tested assemblies fits, our technical application team will work with you and our partners to develop a bespoke assembly and have it tested.

On-site values depend on flanking paths, junctions and penetrations. On request, we can measure the sound insulation in the laboratory or directly on site.

Everything from a single source

Request design documents for this assembly

You will receive the complete package by email, tailored to this assembly. On request, our technical application team will contact you personally.

  • Test report 18-001770-PR02 PB X23-F03-04-de-01Cover sheet
  • ETA-20/0371 PhoneStar acoustic boards
  • Data sheet: PhoneStar ST Tri
  • PhoneStar Tri data sheet
  • Wolf MiWo data sheet
  • Limestone grit fill data sheet
  • Installation instructions for Wolf Bavaria systems
  • Wolf system solutions specification text: solid timber floor
  • Expert opinion on test series 18-001770
  • Personal consultationOur technical application team checks variants for your project
Markus Schramm, Wolf Bavaria, in productionMarkus Schramm as a cartoon character from the explainer video
“My team and I will be happy to help you personally with any technical questions. Please feel free to send us an enquiry.”

Markus SchrammM.Eng., Dipl.-Ing. (FH)
Head of Technical and Building Acoustics

Request documents

Assembly: BHB 1.10 20 mm MiWo + DHB M 1.3 ST Tri