Timber joist floor in an existing building with dry screed and suspended ceiling

System designation BHA_1.2_DHA H 1.2

Build-up from the top Endbelag/18 GF/20 WPF Light/12,5 ST Tri/3 Vlies

Tested floor assembly for the refurbishment of an existing timber joist floor. In the laboratory, the assembly achieves a weighted normalised impact sound pressure level of 43 dB and a weighted sound reduction index of 70 dB. The assembly is installed completely dry, with no drying time. On the underside, a ceiling lining (TPS25 profiles with clips) adds to the sound insulation.

Section drawing · dimensions in mm
43dB
Impact sound Ln,wCI = 4 dB · laboratory
70dB
Airborne sound RwLaboratory
365.5mm
Total build-upincluding the structural floor
REI45
Fire resistance from belowfrom above: F30-B
Bestseller for concrete floor slabs
Wolf Bavaria system assembly

The assembly layer by layer

Section drawing and isometric view of the tested assembly BHA_1.2_DHA H 1.2, with all layer thicknesses. Select a layer in the drawing, the legend or the layer list to see its function.

Total thickness incl. structural floor Impact sound Ln,w = 43 dBAirborne sound Rw = 70 dBDry screedUnderfloor heating integratedValues according to the test report
Tip: use ↑ ↓ to step through the layers
ItemLayerThickness [mm]
In brief

Key facts at a glance

  • Tested: Impact sound Ln,w = 43 dB and airborne sound Rw = 70 dB in the laboratory, documented in the test report.
  • Dry installation: no drying time, so the following trades can start promptly.
  • 365.5 mm total build-up including the structural floor, with integrated underfloor heating.
  • All documents free of charge: Section drawing, test report, specification text and data sheets as PDFs by email.

Request planning documents

Explainer video · 1:40

System assemblies explained in 100 seconds

Architect Tina designs, developer Thorsten needs the evidence, building physicist Patrick checks it. Markus Schramm shows why our system assemblies are already tested and how our technical application team supports you with your own assemblies.

Ask a technical question
Explainer video thumbnail, system assemblies: over 50 tested assemblies 1:40

The video is only loaded from YouTube when you play it.

For your design

What this assembly means for you

Designers, tradespeople and developers look at different details. Choose who you are.

Design
Installation
Build and buy
Cartoon figure of architects

Design

Architects

What do I need to know for design and tendering?

  • 365.5 mm total build-upIncluding the structural floor. Mass per unit area on request.
  • Fire resistanceFrom above F30-B, from below REI45.
  • Ceiling liningTPS25 profiles with clips.
  • Use categoryA1–B2.
  • Ready for tenderItem-by-item specification text for all layers, matching the tested assembly.
Technical data

All performance values at a glance

The values are taken from the test report. They apply to the laboratory test rig without flanking transmission; values in the building depend on the junctions.

System designation
BHA_1.2_DHA H 1.2
Build-up from the top
Endbelag/18 GF/20 WPF Light/12,5 ST Tri/3 Vlies
Floor type
Existing timber joist floor
Screed
Dry screed
Ceiling lining
TPS25 profiles with clips
Weighted normalised impact sound pressure level
Ln,w (CI) = 43 (4) dB
Weighted sound reduction index
Rw = 70 dB
Total build-up thickness
365.5 mm
Use category
A1–B2
Fire resistance from above
F30-B
Fire resistance from below
REI45
Test evidence
Test report Altbaudecke_WolfBavaria
Manufacturer
Wolf Bavaria GmbH, Heilsbronn

Good to know

Need a different assembly? If none of our tested assemblies fits, our technical application team will work with you and our partners to develop a bespoke assembly and have it tested.

On-site values depend on flanking paths, junctions and penetrations. On request, we can measure the sound insulation in the laboratory or directly on site.

Variants

Similar assemblies: existing timber joist floor

Assemblies on the same floor type with comparable performance data. For both values, a longer bar means better sound insulation: lower impact sound level, higher airborne sound insulation.

VariantLn,wRwThickness
BHA_1.2_DHA H 1.2Existing building · Best seller43 dB70 dB365.5 mmThis page

You will find all 55 floor assemblies, with filters and direct comparison, in the Assemblies overview →

Everything from a single source

Request design documents for this assembly

You will receive the complete package by email, tailored to this assembly. On request, our technical application team will contact you personally.

  • Test report Altbaudecke_WolfBavariaCover sheet
  • Installation instructions for Wolf Bavaria systems
  • Wolf system solutions specification text: timber joist floor
  • Personal consultationOur technical application team checks variants for your project
Markus Schramm, Wolf Bavaria, in productionMarkus Schramm as a cartoon character from the explainer video
“My team and I will be happy to help you personally with any technical questions. Please feel free to send us an enquiry.”

Markus SchrammM.Eng., Dipl.-Ing. (FH)
Head of Technical and Building Acoustics

Request documents

Assembly: BHA_1.2_DHA H 1.2