Soundproofing between floors in a timber joist floor means improving its airborne and, above all, its impact sound insulation through added mass, decoupling and cavity damping. Typical measures are a heavy floating dry screed, pugging or added weight on the subfloor, insulation between the joists and a resiliently suspended ceiling.
- Timber joist floors are lightweight. Their main problem is low-frequency footfall noise, perceived as thudding and booming.
- Mass is the most important lever: on top as a heavy screed and as added weight on the subfloor.
- Decoupling on top with impact sound insulation and below with a resiliently suspended ceiling interrupts structure-borne sound.
- Insulation between the joists damps the cavity, but has little effect on its own.
- To assess low frequencies, the spectrum adaptation term CI,50-2500 is more meaningful than the single-number rating alone.
Why timber joist floors let so much sound through
A timber joist floor consists of joists, boarding or floorboards on top and often a ceiling lining underneath. Compared with a reinforced concrete slab it is very light. For airborne sound, this can be offset well with twin-leaf constructions. With impact sound, however, the problem of low frequencies remains: footsteps, children and chairs being moved excite the light floor strongly, and the low-frequency components below 100 Hz in particular arrive in the room below as thudding. The single-number rating L′n,w alone captures this only partially, which is why the spectrum adaptation term CI,50-2500 is also considered for timber floors. It extends the assessment down to 50 Hz and shows how well a floor protects against footfall noise. According to research by Rabold and Hamm, a value of Ln,w + CI,50-2500 ≤ 53 dB corresponds roughly to a maximum footfall noise level LAF,max of 35 dB(A) in the room below; above that, disturbing transmission is to be expected.
Four levers for soundproofing between floors

1. Heavy dry screed on impact sound insulation
A floating screed forms a mass-spring-mass system together with the impact sound insulation and the subfloor. The heavier the upper layer, the lower the resonance frequency and the more effective the decoupling. On timber joist floors, dry screeds are generally used because they do not introduce water into the structure. Heavy boards with high mass at low thickness, such as PhoneStar made of quartz sand and honeycomb board, have the advantage here.
2. Pugging or added weight on the subfloor
Mass placed directly on the subfloor makes the lower layer heavier and less responsive to vibration. Older buildings often contain historic pugging of clay or sand. In new builds and refurbishment, dry fill, chippings or weighting boards are used. It is important that the fill is bound or secured against shifting, and that a membrane stops it from trickling through gaps. The floor must be able to carry the additional load.
3. Cavity damping between the joists
Mineral wool or wood fibre between the joists damps standing waves in the cavity. This mainly improves the airborne sound insulation of twin-leaf constructions. Against impact sound, cavity damping alone has little effect; it complements mass and decoupling.
4. Resiliently suspended ceiling
A ceiling screwed directly to the joists vibrates along with them. If, on the other hand, it is fixed via resilient bars or decoupled hangers, a second mass-spring-mass stage is created. The heavier the lining, for example with two layers of board, the better. In listed rooms with exposed beams or ornamental plaster ceilings, this option is often not available. The measures from above then have to work all the harder.
What the measures achieve
Published laboratory measurements on a typical timber joist floor from an older building show how large the effects are. The untreated reference floor achieved Ln,w 69 dB and Rw 47 dB. With a suspended ceiling of two layers of fire-resistant board and 40 mm of mineral wool, the impact sound level fell to 56 dB and the airborne sound insulation rose to 53 dB. With an additional 100 mm of bound fill and a screed element on mineral wool, Ln,w 38 dB and Rw 78 dB were achieved.
Our own laboratory test series also show where the levers lie. The values apply in each case to the tested overall build-up and cannot simply be transferred to other floors:
- A ceiling with PhoneStar instead of plasterboard alone improves Ln,w by 14 to 17 dB.
- An additional PhoneStar layer on a resiliently suspended ceiling improves Ln,w + CI,50-2500 by 9 dB.
- 80 mm instead of 60 mm of chippings fill gains 3 dB, 80 mm instead of 40 mm gains 6 dB.
- Without fill and with a rigidly fixed ceiling, airborne and impact sound performance each worsen by 14 dB.
New build or existing building: the differences
| Topic | New build | Existing building |
|---|---|---|
| Design | Free choice of build-up, tested systems to DIN 4109-33 or test certificate | Survey the existing floor first: joists, floorboards, old pugging, moisture |
| Build-up height | Allowed for in the design | Often the bottleneck because of doors, stairs and thresholds |
| Spare load capacity | Calculated in the design | Must be checked before any additional mass is added |
| Ceiling below | Usually straightforward | Often not possible with ornamental plaster or exposed beams |
| Requirement (Germany) | DIN 4109-1, for timber floors L′n,w ≤ 53 dB | For conversions of buildings completed before 1 July 2016, L′n,w ≤ 53 dB |
What matters on site
- Fit edge insulation strips at all walls and penetrations, and only trim the excess after the floor finish has been laid.
- Fix loose floorboards before installation so that nothing creaks.
- Do not forget the membrane under any fill.
- Fix the ceiling only via the specified resilient bars or hangers, never additionally direct to the joists.
- Route pipes and cables with resilient fixings and seal openings acoustically.
- For separating floors between flats, think about flanking paths. Continuous floorboards or joists running under separating walls carry sound into the neighbouring flat.
For timber joist floors we offer tested build-ups with PhoneStar dry screed, pugging and suspended ceiling. Our most requested build-up achieves Rw 78 dB and Ln,w 41 dB in the laboratory, and its fire classification F30-B from above and REI 45 from below is documented by a German general building authority test certificate (abP). You will find an overview on the page Sound insulation for timber joist floors and in our system build-ups. For refurbishment projects, our checklist for renovating older buildings is also worth a look.
Frequently asked questions
The most effective approach combines a heavy floating dry screed on impact sound insulation, pugging or added weight on the subfloor and a resiliently suspended ceiling. Insulation between the joists complements this.
Timber joist floors are light and are strongly excited by footsteps. Low frequencies below 100 Hz in particular are transmitted well and perceived as thudding. Mass and decoupling are what help most.
No. Insulation in the cavity only damps the void and mainly improves airborne sound insulation. Against impact sound you also need mass and decoupling above and below.
It is a spectrum adaptation term for impact sound that extends the assessment down to 50 Hz. It is added to the impact sound level and gives a better picture of how much low-frequency footfall noise is transmitted. It is particularly meaningful for timber floors.
In Germany, DIN 4109-1 requires an impact sound level of no more than 50 dB for a separating floor between flats in an apartment building. For floors in timber, lightweight and drywall construction to DIN 4109-33, up to 53 dB is permitted, as it is for conversions of buildings completed before 1 July 2016. In England and Wales, separating floors are assessed against Approved Document E instead.
Yes, with dry underfloor heating systems that need little build-up height and introduce no water into the structure. The heating is integrated into the dry screed build-up.
Sources
- DIN 4109-1:2018-01 Sound insulation in buildings, Part 1: Minimum requirements. DIN Media.
- DIN 4109-33:2016-07 Sound insulation in buildings, Part 33: Component catalogue for timber, lightweight and drywall construction. DIN Media.
- DIN EN ISO 717-2:2021-05 Rating of sound insulation in buildings and of building elements, Part 2: Impact sound insulation. DIN Media.
- Saint-Gobain Rigips: Technik Aktuell No. 64, Schallschutz von Holzbalkendecken, 10 December 2020.
- Rabold, Hamm: Schall- und schwingungsoptimierte Holzdecken, in: Zukunft Holz, chapter 11.2.
- Holzforschung Austria et al.: Resonanzfrequenzen und Trittschallübertragung, final report, November 2024.
- Wolf Bavaria: Sound insulation for timber joist floors, system page and system build-ups.


