PowerFloor Underfloor Heating – Dry system for floors, walls and ceilings
Why use underfloor heating in drywall construction?
Why, how and what makes PowerFloor so special! One product range, several system variants, plus a wet system. Here you’ll find all the information you need about the PowerFloor principle and which system is used in which situations.
Lower thermal inertia – faster control:
A traditional underfloor heating screed has a high thermal mass. This certainly has its advantages: the floor can store heat, even out temperature peaks and release the heat evenly over a longer period. Where heating requirements remain largely constant, this inert behaviour can be beneficial.
However, if heating requirements change at short notice, the thermal mass becomes a disadvantage. Before a solid underfloor heating screed can release its full output into the room, a significant proportion of the screed mass must first be heated up. If the heating is subsequently turned down, the stored heat is retained and continues to be released into the room.
Particularly where room usage varies or additional heat is gained from sunlight, people and electrical appliances, this can cause the room temperature to rise above the desired level. Predictive control can reduce this effect, but cannot eliminate it entirely.
PowerFloor therefore relies on low thermal inertia. The heating pipes are located close to the surface, whilst the aluminium heat-conducting plates distribute the heat quickly and evenly across the surface. Compared to a solid wet screed, significantly less material needs to be heated. The system thus reaches its heating capacity more quickly and responds more rapidly to changes in actual heat demand.
The low thermal mass does not automatically save energy. However, it creates the conditions for more precise and demand-responsive control and can reduce unnecessary reheating or overheating of the room.
Added to this are the advantages of the dry and lightweight construction: PowerFloor introduces no additional construction moisture into the building, requires no drying-out period and does not necessitate functional heating to dry the screed. The low weight and slim profile are particularly advantageous in renovation projects and on existing timber-beamed ceilings.
PowerFloor does not, therefore, completely dispense with heat storage. Rather, the system deliberately reduces the amount of heat stored in the heating structure and transfers the heat more quickly to where it is needed: to the floor surface and into the room.
How the PowerFloor element works
The principle behind our dry-installation underfloor heating system
The principle is simple, the effect is not. Three processes work together.
1. The Honeycomb Carries the Load
The core of the element is a honeycomb panel made of cardboard. Honeycombs are what nature builds when maximum load-bearing capacity is needed with minimum material use. That’s why the PowerFloor element holds 500 kPa compressive strength, across the entire surface and without deformation right up to the edge.
2. The Heat-Conducting Plate Distributes the Heat
In conventional dry systems, heat sits where the pipe runs, and it stays cooler in between. This creates a striped pattern across the floor surface.
The embedded aluminum heat-conducting plate picks up the heat at the pipe and carries it out across the surface. Instead of localized pockets of heat above the pipes, a homogeneous heat distribution develops across the entire floor. At a 125 mm pipe spacing, the surface is covered practically without gaps.

3. The Low Mass Responds Quickly
Because there is barely any mass between the heating pipe and the floor covering, barely any mass needs to be heated up either. The heating responds to a change in demand within minutes.
This isn’t just a comfort detail, it’s the reason for the energy savings: where a sluggish wet screed overshoots the setpoint and then reheats unnecessarily, PowerFloor tracks the curve precisely. In practice, this amounts to around 16% energy savings compared to a sluggish wet screed assembly, especially with night setback. In fairness, we should mention that this depends heavily on the exact assembly. We’re happy to share our expertise and advise you in detail on your specific setup.
PowerFloor 3-in-1
The interplay of these three processes can be summarised in three characteristics:
Compression-resistant. Ultra-light. Fast.
- Compression-resistant: 500 kPa across the entire surface right up to the edge
- Ultra-light: from approx. 2.1 kg/m² in weight per unit area
- Fast: reacts within minutes, no drying time, can be walked on immediately
This combination makes PowerFloor a system that differs fundamentally from mass-based heating systems: it not only heats the floor structure, but also heats the room efficiently.
What this type of underfloor heating means for the construction process:
- No drying-out time, no heating costs during the construction phase
- Quickly ready for the top layer
- Can be walked on and bear loads immediately after installation
- Installation height 20–30 mm, weight per unit area from approx. 2.1 kg/m²
- Ideal for low-temperature heating systems, heat pumps and solar thermal systems
- Can also be connected to an existing heating system using a fixed-value control kit
- Flexible interior design, full-surface underfloor heating, pleasant radiant heat
- Day and night control, rapid heating and cooling times
Heating and cooling via the floor, walls and ceiling
PowerFloor is not just a floor system. The same elements work on walls, in sloped ceilings, and on ceilings, and in summer also as surface cooling.
| Installation Location | Cooling Output* |
|---|---|
| Floor | up to 31 W/m² |
| Wall | up to 41 W/m² |
| Ceiling | up to 37 W/m² |
* at 8 °C spread. Build height for wall and ceiling heating: 30 mm.
The complete heating output tables for all systems can be found in our planning folder or in our download area.
We provide installation instructions and installation videos for all our products,
which work in practice.
Watch the PowerFloor installation video now!
Because we know what’s needed out there
Products that are practical and easy to install.
M. Wolf
CEO, Wolf Bavaria
PowerFloor formats and technical specifications
Element formats:
- Straight element: 1000 × 500 mm, thickness 20 / 24 / 30 mm depending on the system
- Deflector element: 250 × 500 mm, thickness 20 / 24 / 30 mm depending on the system
- Installation height for wall and ceiling heating: 30 mm
Pipe: Plastic-aluminium composite pipe 16 × 2.0 mm, available in 100 m, 200 m or 500 m rolls
Compressive strength: 500 kPa, all systems
Weight per unit area: approx. 2.1 kg/m² (Light), approx. 2.6 kg/m² (Slim), approx. 2.5 kg/m² (Nature)
Storage and handling:
- Store PowerFloor panels flat, exclusively indoors, in a dry, frost-free environment and protected from direct sunlight
- Store at the installation site for 24 hours to allow acclimatisation
- Protect edges from damage
Environmental conditions during installation: minimum room temperature of 10 °C, 30–60 % relative humidity, enclosed and frost-free rooms, windows fitted and glazed.
Material requirements: Allow for approx. 5 % wastage.
Our complete sets include the installation plan and precise material calculations to ensure your project is a guaranteed success. We’re always here when you need us!
PowerFloor Underfloor Heating Certification
PowerFloor is made from environmentally friendly raw materials, is almost entirely recyclable and is produced sustainably.
- Listed in the DGNB Navigator
- EPD declaration
- QNG Ready (Certified sustainable product)
- Can be dismantled and recycled
- Free from harmful substances
Tested. Listed. Safe.
Businesses and private customers all over the world place their trust in our PowerFloor underfloor heating system.
On-site installation
Simple Installation: What Matters on the Construction Site
We designed PowerFloor from the start to be simple and quick to install. Every product comes with a matching installation guide.
Installation Times, per Person
| Installation Method | Time |
| Floating on a wood or mineral substrate (without pipe) | 10–20 min/m² |
| Glued on wood (Wolf roller adhesive / Wolf system adhesive) | 12–22 min/m² |
| Glued on a mineral substrate | 12–24 min/m² |
| Pipe installation (with a pipe laying device) | 2–4 min/m² |
Included is the installation of the edge insulation strip and the PowerFloor elements, including cutting to size.
Not included are moisture and vapor barriers, additional insulation, reinforcement layers and floor coverings, material transport, filling, sanding and priming, manifold installation, as well as trial heating and balancing of the heating circuits.
How PowerFloor works in refurbishment projects
PowerFloor really comes into its own in existing properties. The panels are slim, lightweight and can be installed without introducing moisture. Whereas a wet screed would place excessive structural strain on old floors and require weeks to dry, PowerFloor can bear loads immediately.
Houses and flats that have previously been heated by radiators can be converted to an underfloor heating system at a comparatively low cost. This also paves the way for a heat pump, as underfloor heating operates at low flow temperatures.
Increasing the value of your property
Basis: Detached house from 150 m². The choice of system affects not only the construction time, but also the construction costs and the long-term value of the property. In our experience, property owners undertaking refurbishment projects benefit from an increase in value of up to 500 euros per square metre when using the PowerFloor Light system. This combines efficient heating technology with a sustainable investment.
PowerFloor in certified ceiling systems
PowerFloor forms part of numerous certified floor systems from Wolf Bavaria, in conjunction with PhoneStar.
Solid timber floor with vibration-damping hangers Construction: 18 mm Wolf Hugo GF precast screed, 20 mm Wolf PowerFloor Light, 2 × 12.5 mm PhoneStar ST Tri, 20 mm Wolf MiWo 20-2 with PhoneStar Schalli around the perimeter, 80 mm cement-bound chippings, 140 mm solid timber floor, 60/40 battens with insulation, 25 mm TPS vibration isolators, 12.5 mm PhoneStar ST Tri, 12.5 mm plasterboard. Total thickness 393 mm, airborne sound insulation 75 dB Rw, impact sound insulation Ln,w = 28 dB, usage category A1 to B1.
PhoneStar and PowerFloor on loose-fill insulation and MiWo Total thickness 315 mm, airborne sound insulation 72 dB Rw, impact sound insulation ΔLn,w = 37 dB, usage category A1 to A3.
PhoneStar and PowerFloor on MiWo total thickness 255 mm, airborne sound insulation 66 dB Rw, impact sound insulation ΔLn,w = 27 dB, usage categories A1 to B1.
Both the thickness and the type of impact sound insulation influence the level of sound insulation. Many other installation variants are possible. Test reports available on request.
As a company, we have a responsibility!
Stillstand ist für uns keine Option.Standing still is not an option for us.
Combining with PhoneStar
The Three Musketeers of sound insulation, sound decoupling and underfloor heating.
All for one & one for all.
Warmth and tranquillity in a single installation. PhoneStar sound insulation boards beneath the PowerFloor system ensure that the floor is not only warm but also quiet. In the wet system, PhoneStar ST Tri is an integral part of the installation.
Wet system? Yes, there’s also a solution for wet screed. Please feel free to ask us.
The combination is modular and can be installed at any time, even retrospectively.
Example construction comprising two layers of PhoneStar,
Powerfloor and a top layer.
The modular system with PowerFloor
PowerFloor is rarely used on its own. The fully dry system solution from Wolf Bavaria comprises:
- Underfloor heating (PowerFloor)
- Dry screed (PhoneStar or Wolf Hugo)
- Sound insulation (PhoneStar)
- Levelling (Wolf Cell)
- Comprehensive range of accessories
The benefits:
- Quick, easy and clean to install
- Environmentally friendly and cost-effective
- No additional moisture
- Natural raw materials
- Fully removable
We’d be happy to help you make the right choice, with no obligation, and offer specific advice on your building project.
Dry system versus wet screed underfloor heating
You don’t want moisture in your own four walls, right?
So why bring in liters of water in the first place, when it also works perfectly well dry?
| PowerFloor Dry System | Wet Screed Underfloor Heating | |
|---|---|---|
| Construction time | No drying time, immediately walkable, quick floor covering readiness | Drying time required, trade blocked afterward |
| Build height | 20–30 mm | Significantly higher, loss of room height |
| Response time | Minutes, no overheating | Sluggish, stores heat, overshoots |
| Energy | Approx. 16% savings, no heating costs during the construction phase | Heating costs during the construction phase |
| Compressive strength | 500 kPa across the entire surface, right up to the edge | Depends on the insulation material underneath |
| Deconstruction | Reversible and recyclable | Screed must be chiseled out |
| Planning | Installation plan, material list, and pipe lengths from a single source | Coordination of multiple trades |
Choosing the right underfloor heating system is very simple
Underfloor heating in 3 steps:
Step 1: Fill in the contact form, initial assessment We examine the specific building situation: subfloor, available installation height, heating requirements, final floor covering, existing property or new build.
Step 2: System proposal and preliminary plan We propose the most suitable system, determine the location of the heating circuit manifold and calculate the materials required.
Step 3: Installation plan and kit You’ll receive the final installation plan on your floor plan, showing all heating circuits, pipe lengths and cut-to-size pieces, along with the complete list of materials and the kit containing all the parts.
Ecology and demountability
At PowerFloor, sustainability doesn’t stop at the raw materials; it extends right through to deconstruction.
The elements are made from environmentally friendly base materials and are almost entirely recyclable. There are no composite materials that cannot be separated later on; instead, the structure can be taken apart at the end of a building’s life. Anyone who has ever had to chisell out a screed will understand why this point is important to us.
Then there’s the operational side: a system that responds quickly and operates at low flow temperatures saves energy throughout its entire service life. Here, sustainability isn’t an added bonus, but a direct consequence of the design.
Haven’t we always done it differently?
Then it’s time. Over 2,000 customers have been relying on our products for more than 20 years – not because they’ve stood still, but because they’ve continued to evolve. Towards better alternatives and more sustainable construction methods that are right on trend! Today is a good day to make the switch.
We won’t leave you to it on your own. For your first project, we’ll guide you personally, step by step, until you’ve got the process under your own control. That’s how we understand partnership on equal terms.
Take the first step. We’ll take the second and the third.
Arrange a meeting now.