From performance declarations to test certificates, bid documents, and installation instructions: All documentation for our systems is available here for you—up-to-date and accessible without registration. If you can’t find a document or need information for your project that isn’t listed here, just contact us. We’ll send you the relevant documentation and, if needed, provide direct advice on your specific installation.
Installation Instructions and Videos
Proper installation is half the battle when it comes to insulation. In our installation guides, you’ll find all the steps, connection details, and requirements for your project—step by step and with no room for interpretation. For those who’d rather watch than read: on our YouTube channel, we demonstrate the same steps in a video filmed right on the job site. This is also ideal for employees who don’t speak or read German.
Installation Instructions
A guide to all our products. To keep the construction site free of clutter. And here’s what you need
Installation Videos
Watch instead of reading.
All the steps are shown in the video, filmed on the construction site.
Knowledge about soundproofing, fire protection, and more
Whether it’s wet or dry construction, wood construction or masonry—we always have the right solution in mind. Here you’ll find our top three resources for an initial consultation, featuring verified information developed in collaboration with building physicists, engineers, construction experts, and scientists.
General Brochure
All Wolf Bavaria system solutions for floors, walls, and ceilings at a glance. Sound insulation, decoupling, radiant heating, and dry screed for new construction and renovation.
Sound Insulation Compendium: Wood Construction
Planning guidelines for the calculated sound insulation verification of wood-frame and solid wood ceilings. Includes tested configurations, performance values, and details for the bid.
Sound Insulation Compendium: Solid-Wall Construction
Design guidelines for mineral-based floor screeds in concrete construction, precast concrete construction, and renovation projects. Includes systems for radiant floor heating and dry screeds, along with technical specifications.
Power-Floor
All the information about our PowerFloor radiant heating system for floors, walls, and ceilings.
EPD
Transparency down to the last detail. Our Environmental Product Declarations provide independently verified life cycle assessment data in accordance with ISO 14025 and EN 15804, prepared and reviewed by kiwa Ecobility Experts. This allows you to clearly demonstrate the environmental benefits of our products in sustainability certifications such as DGNB, LEED, or QNG—without estimates and without having to contact the manufacturer for clarification.
EPD PhoneStar
Environmental Product Declaration (EPD) in accordance with ISO 14025 and EN 15804 for the PhoneStar panel. Verified life cycle assessment data for sustainability certifications such as DGNB, LEED, and QNG.
EPD PhoneStrip
Environmental Product Declaration (EPD) in accordance with ISO 14025 and EN 15804 for the PhoneStrip decoupling strip. Verified performance data covering the entire life cycle for your building assessment.
EPD PowerFloor
Environmental Product Declaration (EPD) in accordance with ISO 14025 and EN 15804 for the PowerFloor heating element. Reliable environmental data for the ecological assessment of your radiant floor heating system.
Price List
Everything comes at a price with us. Note: Don’t compare apples to oranges—compare apples to apples and oranges to oranges. Prices per square meter tell you how much a square meter costs. But with our products, you also save on construction time, reduce material costs thanks to thinner installations, and gain additional marketable space. We’d be happy to calculate your potential savings for you. Our service also pays off. With our PowerFloor underfloor heating system, for example, the material calculation and installation plan are included by our planning team.
Heating and Cooling Capacity Tables
Here you will find the heat output tables for all PowerFloor systems. They show the heat output and surface temperature for each type of flooring, installation spacing, and flow temperature, as well as the values for ceiling and wall coverings in both heating and cooling modes. This allows you to accurately verify your system design without relying on estimates.
Heating Capacity Tables: System Light
Heating output and surface temperatures for direct installation. Values for laminate, hardwood, and wood planks with installation spacing of 125 and 250 mm.
System Heating Capacity Table Slim
Heating capacity and surface temperatures for direct contact in the Slim configuration. Complete performance data for each floor covering and flow temperature.
Heating Capacity Tables: System ÖkoPlus
Heating output and surface temperatures for direct installation in the Öko Plus system. All values are specific to the floor covering, installation spacing, and flow temperature.
Heating Capacity Tables for the Nature System
Heat output and surface temperatures for direct contact in the “Nature” configuration. Design basis for your calculation in accordance with DIN EN 1264.
Heating and Cooling Capacity Ceiling
Performance specifications for ceiling cladding with 12.5 mm gypsum fiberboard. Specifications for heating and cooling operation, including flow temperatures.
Heating and Cooling Capacity - Wall-Mounted
Performance specifications for wall cladding with 12.5 mm gypsum fiberboard. Performance characteristics for heating and cooling operation, including flow temperatures.
Adhesive Recommendations
Here you will find our partners’ recommendations for adhesives and installation procedures for laying flooring on Wolf Bavaria subfloors. For each manufacturer, you’ll find the appropriate adhesive, notching, and coverage rates, tailored for dry screed, PowerFloor, and PhoneStar.
Bona Adhesive
Bona’s installation recommendations for hardwood flooring on Wolf Hugo N+F gypsum fiberboard. Includes adhesive recommendations by flooring type and coverage information.
Bostik Adhesive
Adhesive recommendations for ceramic tiles, hardwood flooring, and top floor coverings on PowerFloor, PhoneStar, and Wolf Hugo N+F. Includes notching and substrate preparation.
Adhesive Kiesel
Installation recommendations for cork, textile, PVC, and rubber flooring, as well as hardwood flooring, on Wolf Hugo N+F. Includes primer, filler, and adhesive for each type of flooring.
Mapei Adhesive
Recommended installation system for Wolf Hugo N+F gypsum fiberboard. From the primer coat to the final flooring, including ceramic tile, natural stone, hardwood, and resilient flooring.
Schönox Adhesive
Recommended adhesives for textile floor coverings, CV, linoleum, PVC, rubber, and hardwood flooring on Wolf Hugo GF precast screed. Includes notches and coverage per adhesive.
Sopro Adhesive
Installation recommendations for ceramic tiles and natural stone on Wolf Bavaria dry screed. Includes primer, adhesive, grout, and information on tile sizes.
Adhesive Stauf
Recommendations for installing hardwood and other flooring using Wolf Hugo N+F, PowerFloor, and PhoneStar. Includes adhesive, notched trowel, and usage rates by hardwood type.
Adhesive Wakol
Installation recommendations for hardwood and other flooring installed over Wolf Hugo N+F, PowerFloor, and PhoneStar. Includes adhesive, decoupling, primer, and leveling compound.
RFP Texts
We’re happy to provide you with our bid documents through our partner Heinze, in any format you may need. Select your product, customize the items to fit your project, and copy the text directly into your bill of quantities. If you still need anything else, please feel free to contact us.
You are currently viewing a placeholder content from Default. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationStatements of Performance
Here you will find the Declarations of Performance (DoP) for our products in accordance with the EU Construction Products Regulation. All PhoneStar and PhoneStrip products have European technical approval under EAD 210134-00-1202 and hold ETA-20/0371, tested and monitored by Kiwa in accordance with the AVCP System 3.
PhoneStar Performance Statement
Collective declaration for all PhoneStar panel formats: Tri, Plus Tri, Twin, ST Twin, and PhoneStar 25. Includes bulk density, compressive strength, flexural strength, and fire performance.
PhoneStrip Performance Statement
Collective declaration for all PhoneStrip widths from 50 to 240 mm, blue and black tape. Includes fc, k, deformation values, and Kij values for L- and T-joints.
Performance Specification: PhoneStar Schalli 15 mm
Non-load-bearing acoustic decoupling strip, 1200 x 60 x 15 mm, Item No. 1025. Approved for interior walls and ceilings.
Performance Specifications for PhoneStar Schalli 25 mm
Non-load-bearing acoustic decoupling strip, 1200 x 60 x 25 mm, Item No. 1026. Approved for interior walls and ceilings.
Technical Data Sheets