Soundproofing solutions for timber-beamed ceilings
Explained using our best-selling set-up as an example
Using this example, we explain how the individual layers function.
Best-selling timber beam ceiling
The complete ceiling build-up as a construction section, the way it is read in planning and in the workshop. Select a layer in the drawing, the legend or the layer list to see its function and test results.
| Pos. | Layer | Thickness [mm] |
|---|
1. Dry screed and heating
1. Dry screed and underfloor heating
Durable, dry and suitable for underfloor heating
Components
18 mm Wolf HUGO GF precast screed
20 mm Wolf PowerFloor Light
2 x 15 mm PhoneStar Tri
The Wolf HUGO GF precast screed distributes the loads and creates a resilient surface. The Wolf PowerFloor system allows for the integration of a responsive underfloor heating system.<br>
The heavy yet flexible PhoneStar boards increase the mass of the floating screed and improve its acoustic performance. This creates a completely dry floor structure that combines sound insulation, load distribution and underfloor heating. The gypsum fibreboard also ensures compliance with fire resistance class F30B in the event of fire exposure from above.
2. Impact sound insulation
2. Impact sound insulation
Elastic separation between the screed and the structural floor slab
Components
20 mm wood fibre insulation board in accordance with the assessed construction
The impact sound insulation decouples the floating dry screed from the load-bearing ceiling structure. This reduces the direct transmission of footfall noise and other structure-borne sound impulses.
Low dynamic stiffness is acoustically beneficial. At the same time, the insulation layer must have sufficient compressive strength to ensure that the floor remains fit for purpose in the long term under the intended live loads. The choice of material must therefore always be tailored to the screed, the usage category and the expected loads.
Studies on solid timber ceilings have shown that mineral fibre products with similar compressive strength generally perform slightly better than wood fibre insulation boards. When using 12 to 20 mm Wolf MiWo, we therefore anticipate an improvement of 1 to 2 dB.
3. Mass
3. Weighting
More mass for better low-frequency sound insulation
Components
80 mm bonded gravel fill
The heavy gravel fill increases the mass of the lightweight timber-beam floor. This reduces the excitation of the bare floor and improves airborne and impact sound insulation, particularly in the low-frequency range, which is crucial for building acoustics.
The test series demonstrates the significant influence of this layer:
Reduction from 80 to 60 mm: additional reduction ΔLn,w = 3 dB
Reduction from 80 to 40 mm: additional reduction ΔLn,w = 6 dB
Complete omission with a rigid sub-ceiling: deterioration of Ln,w by 14 dB and of Rw by 14 dB
4. Load-bearing capacity
4. Load-bearing structure
Load-bearing capacity and cavity damping
Components
22 mm wood-based panel
240 mm solid structural timber
2 x 120 mm mineral wool insulation between the joists
The timber joists bear the structural loads. The voids, which are completely filled with porous fibre insulation, dampen the ceiling cavity and reduce resonance within the structure.
To ensure long-term effective sound insulation, the insulation material should be installed tightly and without any significant gaps between the beams. A minimum infill of 80 per cent of the cavity is mandatory.
5. Suspension
5. Suspended ceiling with PhoneStar
Crucial for the sound insulation of the timber-beamed ceiling
Components
24 mm rigidly fixed battens
12.5 mm PhoneStar ST Tri
12.5 mm plasterboard
In ceilings with wooden beams, the suspended ceiling has a particularly significant influence on the overall sound insulation. The heavy and flexibly compliant PhoneStar board increases the mass of the cladding and improves its acoustic performance.
Even when the battens are rigidly fixed to the timber beams, this results in very good sound insulation. Compared with a suspended ceiling clad solely with plasterboard, the additional PhoneStar layer reduces the standard impact sound level in the test chamber by 14 to 17 dB.
Even higher sound insulation values can be achieved with an elastically suspended sub-ceiling. For this type of sub-ceiling, which offers even greater acoustic performance, the fire resistance under fire exposure from below was also tested: a rating of REI 45 was achieved, documented by a general building inspection test certificate with F30B certification.
Particularly effective at low frequencies
The suspended ceiling offers particularly great acoustic potential, especially in timber-beamed ceilings with deep, insulated cavities. In combination with a resilient suspension system, it forms a largely decoupled second shell. The additional heavy yet flexibly compliant PhoneStar panel increases the mass of this shell and improves the mass-spring-mass system of the entire ceiling structure. The large distance between the shells has a particularly beneficial effect in the critical low-frequency range.
Its effectiveness is confirmed by laboratory measurements: the additional PhoneStar layer on the resiliently suspended sub-ceiling improved the extended assessment value (Ln,w+CI,50–2500 Hz) by 9 dB in a direct comparative test. This not only reduces the rated standard impact sound level; it also provides significantly more effective insulation against the impact sound components between 50 and 100 Hz, which are particularly bothersome in timber-beamed ceilings.
Done!
A fully dry, heatable and load-bearing timber-beam ceiling structure with high mass, effective decoupling and a rigid sub-ceiling suitable for prefabrication.
A tested system solution, tailored to modern timber construction.
We recommend different structures depending on the project requirements.
Please feel free to contact us:
Practical guidance on floor construction
From experience, for practical use. Our products have been in use on construction sites around the world for over 22 years.
In 2024, we celebrated our 20th anniversary.